RSE Series

RSE 2 Series

Raycap RSE 2 Series are Type 1 and Type 2 (filtered) Surge Protective Devices (SPD) suitable for use at the service entrance and distribution panel level. With its date and time-stamped impulse counter, it enables root cause analysis of grid issues.

RSE 2 Series products are Type 1 and Type 2 (filtered) surge protective devices that can be used at the service entrance and/or distribution panel level. The series offers two different protection mode options: a standard all-mode / 7-mode configuration and a 10-mode option including an indirectly connected component.

The most distinctive feature of the series is its date and time-stamped TOV / impulse counter. The device records surge events it is exposed to, along with time information. This allows for root cause analysis when a problem occurs in the distribution network, by identifying when the event happened. This ensures the question "why did the device fail" is answered with data, not speculation.

The product utilizes a stacked MOV design, which ensures balanced current sharing among protection elements, increasing total current handling capacity. It is supplied with an extruded aluminum enclosure, end caps, and nipple connection; the device is pre-wired. LED status indicator, audible alarm, and remote monitoring contacts (RC) are standard.

  • Type 1 and Type 2 (Filtered) SPD
  • Service Entrance and Distribution Panel Level Use
  • Protection Mode Options: 7-Mode or 10-Mode
  • 50 / 100 / 150 / 200 kA Options per Mode
  • Nominal Discharge Current (In): 20 kA
  • Short Circuit Current Rating (SCCR): 200 kA
  • Date and Time-Stamped TOV / Impulse Counter — Root Cause Analysis Capability
  • Stacked MOV Design
  • Increased Current Handling Capacity with Sharing Optimization
  • Low Protection Voltage Levels
  • UL 1449 Listed
  • Extruded Aluminum Enclosure, End Caps, and Nipple Connection
  • LED Status Indicator + Audible Alarm + Remote Monitoring Contacts (RC)
  • Pre-wired Delivery
  • 10-Year Standard Warranty

The RSE 2 Series is preferred in applications where traceability is as important as protection performance:

  • Service entrance (main panel) — First-level protection
  • Main distribution panels — Critical points feeding the entire facility
  • Commercial buildings and business centers — Facilities where downtime and equipment failure are costly
  • Industrial facilities and production lines — Sites requiring investigation into the source of recurring failures
  • Automation and process control systems — Panels supplying sensitive equipment
  • Facilities with power quality issues — Event analysis via meter records
  • Data centers and critical infrastructure — Systems where record-keeping is mandatory
  • Facilities with service and maintenance contracts — Data usable for periodic reporting
  • RSE Commercial-Industrial Surge Protection Reference Guide Download
  • RSE Series 2 to 7 Mode Datasheet Download
  • RSE Series 2, up to 10 Mode Datasheet Download
  • Automatic Systems in Industrial/Commercial Facilities Need Better Surge Protection - Article Download
Please enable JavaScript in your browser to complete this form.
Please enable JavaScript in your browser to complete this form.