The Raycap ACData ACX Series comprises hardwired varistor and hybrid-designed Surge Protective Devices (SPDs). It offers impulse current capacities ranging from 40 kA to 200 kA in an 8/20 µs waveform, with LED status indicators, remote alarm notification, and EMI/RFI filtering options.

The ACData ACX Series consists of varistor (MOV) and hybrid-designed surge protection devices suitable for hardwired installation. The series covers a wide impulse current capacity range, from 40 kA to 200 kA in an 8/20 µs waveform.

A distinguishing feature of the series is its non-reliance on a single technology. Depending on the model, it utilizes advanced coordinated hybrid, common mode, thermally fused varistor (MOV), and/or silicon avalanche diode (SAD) suppression technologies. This versatility allows addressing diverse application requirements within a single series.

Design features vary by model, including LED visual protection status indication, remote alarm notification, and electromagnetic/radio frequency interference (EMI/RFI) filtering. EMI/RFI filtering provides not only surge protection but also improved immunity to grid noise in applications housing sensitive electronics.

Products are listed as Type 1 or Type 2 SPDs under UL 1449 5th Edition. Type 4 outdoor enclosure and wide operating temperature range enable outdoor installations.

  • Hardwired installation
  • Impulse current capacity: 40 kA – 200 kA (8/20 µs)
  • Diverse suppression technologies:
    • Advanced coordinated hybrid
    • Common mode
    • Thermally fused varistor (MOV)
    • Silicon avalanche diode (SAD)
  • LED visual status indicators
  • Remote alarm notification
  • EMI/RFI filtering (model dependent)
  • UL 1449 5th Edition Type 1 or Type 2 SPD listing
  • Type 4 outdoor enclosure
  • Wide operating temperature range

Thanks to its wide capacity range and outdoor compatibility, the ACData ACX Series addresses a variety of applications:

  • Outdoor installations — Building exterior mounting with Type 4 enclosure
  • Sites exposed to wide temperature ranges — Cold and hot climate conditions
  • Facilities housing sensitive electronics — Models with EMI/RFI filtering
  • Main and sub-distribution panels — With Type 1 and Type 2 options
  • Industrial facilities — Points requiring high impulse capacity
  • Telecommunication infrastructures — Field cabinets and remote locations
  • Remotely monitored facilities — Remote alarm notification
  • Multi-point projects with varying requirements — Diverse solutions within a single series