{"id":57409,"date":"2020-01-02T19:44:50","date_gmt":"2020-01-02T16:44:50","guid":{"rendered":"https:\/\/yilkomer.com\/yurtlarda-ag-parafudr-kullanimi\/"},"modified":"2026-08-31T00:27:31","modified_gmt":"2026-08-30T21:27:31","slug":"use-of-ag-surge-arresters-in-dormitories","status":"publish","type":"post","link":"https:\/\/yilkomer.com\/en\/use-of-ag-surge-arresters-in-dormitories\/","title":{"rendered":"USE OF AG SURGE ARRESTERS IN DORMITORIES"},"content":{"rendered":"<div class=\"vgblk-rw-wrapper limit-wrapper\">Dormitories AG Surge Arrester usage is extremely important in order to prevent the triggering of fire risks as a result of possible arcs; system failures due to sudden surges, and most importantly to prevent both fire and system failures caused by a possible lightning strike. Dormitories, where students entrust their lives, are areas where students of all ages live and are without exception evaluated as RISK 1 areas. In every dormitory construction, at least for obtaining a license, an external lightning protection system, predominantly a lightning rod system, is installed on the dormitory roof. The external lightning protection system, which is responsible for receiving the surge and discharging it to the ground, may cause the surge to be induced on electrical systems; it should be remembered that within the scope of Electrical Internal Installation Regulation Article 43, the use of AG Surge Arrester products is mandatory in structures that have an external lightning protection system. In addition, possible sudden peaks and voltage surges that may come from the grid can reach every part of the facility within nanoseconds. In order not to allow more possibilities for fires in our country to be attributed to electrical contact, the use of AG surge arresters in dormitories has now become mandatory in our country.<\/p>\n<p>Dormitories are complex areas that include camera security systems, fire alarm panels, fingerprint reader systems, card access systems; booster and boiler rooms, telecom lines, internet networks, and in some locations more than 1000 people live inside. A lightning strike that may hit a dormitory can disable all of these systems within a time such as 100ns. All dormitory generators may also become de-energized as a result of being disabled due to lightning; they may remain cold in winter. Therefore, AG Surge Arrester systems should be used in dormitories within the scope of IEC 62305 standards. The AG Surge Arrester system should be designed in a coordinated manner in dormitories;<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-8245\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2020\/01\/raycap-yurtlarda-ag-parafudr-kullan%C4%B1m%C4%B1.jpg\" alt=\"urtlarda ag parafudr kullan\u0131m\u0131\" width=\"1402\" height=\"830\" \/><\/p>\n<p>Raycap Protec T1HS Type 1+2+3 100ka 3p+n at the main incoming panel;<\/p>\n<p>Raycap Protec C Type 2 40ka Type 2 3P+N at sub floor panels<\/p>\n<p>Raydat Net6 Poe on Ethernet Poe Lines<\/p>\n<p>Raycap MGZ 10 protection on Telecom Lines<\/p>\n<p>Products such as Raycap Raytel 10 on ADSL Lines should be used as the most basic protection.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-8246\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2020\/01\/raycap-yurtlarda-ag-parafudr-secimi.jpg\" alt=\"yurtlarda ag parafudr secimi\" width=\"1541\" height=\"1895\" srcset=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2020\/01\/raycap-yurtlarda-ag-parafudr-secimi.jpg 1541w, https:\/\/yilkomer.com\/wp-content\/uploads\/2020\/01\/raycap-yurtlarda-ag-parafudr-secimi-244x300.jpg 244w, https:\/\/yilkomer.com\/wp-content\/uploads\/2020\/01\/raycap-yurtlarda-ag-parafudr-secimi-833x1024.jpg 833w, https:\/\/yilkomer.com\/wp-content\/uploads\/2020\/01\/raycap-yurtlarda-ag-parafudr-secimi-768x944.jpg 768w, https:\/\/yilkomer.com\/wp-content\/uploads\/2020\/01\/raycap-yurtlarda-ag-parafudr-secimi-1249x1536.jpg 1249w\" sizes=\"(max-width: 1541px) 100vw, 1541px\" \/><\/p>\n<p>According to the technical characteristics of the dormitory, coaxial lines; satellite lines; single-phase energy lines can also be protected. Here, carrying out a detailed survey study is extremely important.<\/p>\n<p>Dormitories are among the most valuable structures where we entrust our children; therefore, having no protection in a dormitory creates an environment for possible negative situations; as technical personnel, it is absolutely necessary to provide coordinated protection throughout the facility starting from the main panel.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-8247\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2020\/01\/yurt-y%C4%B1ld%C4%B1r%C4%B1m%C4%B1ndan-koruma.jpg\" alt=\"raycap yurt y\u0131ld\u0131r\u0131mdan koruma\" width=\"927\" height=\"1336\" \/><\/p>\n<p>In addition, in terms of external lightning protection, especially external lightning down conductors that come into contact with metal parts such as fire stairs may cause physical injuries. The precaution to be taken in this regard is to discharge the surge safely to the ground by using an insulated lightning down conductor. Insulated lightning down conductors can absorb surges with a peak value of 200ka;<\/p>\n<p>As Y\u0131ld\u0131r\u0131mdan Korunma Merkezi, we provide technical support and free survey services to all interested parties who contact us regarding lightning protection of dormitories. In these years when the lightning risk is increasing in our country, the protection of your educational institutions is extremely important. At this point, we recommend that technical authorities of private facilities as well as public institutions take the necessary precautions regarding lightning protection in dormitories.<\/p>\n<p>For more detailed information about lightning protection and AG surge arrester usage in dormitories, you can contact the Y\u0131lkomer technical team via our contact page.<\/p>\n<p>&nbsp;<\/p><\/div>\n<p><!-- .vgblk-rw-wrapper --><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Dormitories AG Surge Arrester usage is extremely important in order to prevent the triggering of fire risks as a result of possible arcs; system failures due to sudden surges, and most importantly to prevent both fire and system failures caused by a possible lightning strike. Dormitories, where students entrust their lives, are areas where students&#8230;<\/p>\n","protected":false},"author":1,"featured_media":992406,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[5],"tags":[],"class_list":["post-57409","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-general"],"_links":{"self":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts\/57409","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/comments?post=57409"}],"version-history":[{"count":1,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts\/57409\/revisions"}],"predecessor-version":[{"id":994578,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts\/57409\/revisions\/994578"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/media\/992406"}],"wp:attachment":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/media?parent=57409"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/categories?post=57409"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/tags?post=57409"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}