{"id":55363,"date":"2016-11-19T18:16:54","date_gmt":"2016-11-19T15:16:54","guid":{"rendered":"https:\/\/yilkomer.com\/gunes-santralleri-icin-yeni-pv-parafudr-teknolojisi\/"},"modified":"2026-08-22T17:49:15","modified_gmt":"2026-08-22T14:49:15","slug":"new-pv-surge-arrester-technology-for-solar-power-plants-iskra-protec","status":"publish","type":"post","link":"https:\/\/yilkomer.com\/en\/new-pv-surge-arrester-technology-for-solar-power-plants-iskra-protec\/","title":{"rendered":"New PV Surge Arrester Technology for Solar Power Plants | \u0130skra ProTec"},"content":{"rendered":"<div class=\"vgblk-rw-wrapper limit-wrapper\">We observe that solar power plant investments are becoming more widespread in our country day by day. It is of great importance to protect these power plants, which are expected to operate efficiently for 20-25 years, from lightning and sudden <strong><em><a href=\"https:\/\/yilkomer.com\/en\/7-devices-sensitive-to-overvoltages\/\">overvoltage <\/a><\/em><\/strong>impulses. At this point, the correct selection of <em><strong>LV surge arrester<\/strong><\/em> systems can be a lifesaver for a power plant. Indeed, sudden overvoltage impulses are the leading cause of damage to solar power plants with a rate of 45%.<\/p>\n<figure id=\"attachment_5806\" aria-describedby=\"caption-attachment-5806\" style=\"width: 720px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/11\/pv-surge.jpg\"><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-5806 size-full\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/11\/pv-surge.jpg\" alt=\"pv-surge\" width=\"720\" height=\"407\" srcset=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/11\/pv-surge.jpg 720w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/11\/pv-surge-300x170.jpg 300w\" sizes=\"(max-width: 720px) 100vw, 720px\" \/><\/a><figcaption id=\"caption-attachment-5806\" class=\"wp-caption-text\">Sudden overvoltage impulses are the most important reason for damage to solar power plants<\/figcaption><\/figure>\n<p>In this article, we will talk about the DC energy part, which is generally more difficult to protect and where errors are often made.<\/p>\n<h2><span style=\"color: #ff6600;\"><strong>Problems Experienced in DC Surge Arresters<\/strong><\/span><\/h2>\n<ul>\n<li>Arc formation in the surge arrester, overheating, and fire risk<\/li>\n<li>The surge arrester not providing the desired lifespan<\/li>\n<li>Variable nature of the DC load<\/li>\n<li>Occurrence of burning due to overload<\/li>\n<\/ul>\n<p><a href=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/11\/protec.jpg\"><img decoding=\"async\" class=\"wp-image-5808 alignleft\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/11\/protec.jpg\" alt=\"protec\" width=\"278\" height=\"350\" srcset=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/11\/protec.jpg 558w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/11\/protec-238x300.jpg 238w\" sizes=\"(max-width: 278px) 100vw, 278px\" \/><\/a>One of the problems frequently encountered with surge arresters on the market is that due to the long distance between the MOV and the disconnector, when a heat increase occurs in the surge arrester, it is detected very slowly by the MOV. In <em><strong>Protec<\/strong><\/em> technology, the electrodes are soldered onto the MOV.<\/p>\n<p>However, there is a physical barrier between the MOV and the electrodes. The existing rotating disk reacts in less than 1 second, ensuring the safe disconnection of the MOV from the system in the surge arrester. Thus, the <strong>MOV<\/strong> is protected when an excessive impulse or energy comes to the surge arrester. In addition, this physical barrier prevents the arc event that occurs especially in <em><a href=\"https:\/\/yilkomer.com\/ag-parafudr\/\"><span style=\"color: #ff6600;\"><strong>DC surge arresters<\/strong> <\/span><\/a><\/em>. As <span style=\"color: #ff6600;\"><em><strong>Y\u0131lkomer<\/strong> <\/em><\/span>, we recommend <span style=\"color: #ff6600;\"><em><strong>Type 1+2+3 <span style=\"color: #000000;\">surge arresters<\/span><\/strong><\/em><\/span> with Safetec Technology on the DC and AC sides for a longer-lasting and safer power plant.<\/p>\n<blockquote>\n<p style=\"text-align: center;\"><a href=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/12\/dc-parafudr-b-s%C4%B1n%C4%B1f%C4%B1.pdf\"><em><strong>Download Technical DataSheet<\/strong><\/em><\/a><\/p>\n<\/blockquote>\n<h3><span style=\"color: #ff6600;\"><strong>Why Type 1+2+3?<\/strong><\/span><\/h3>\n<p>Unfortunately, most inverters sold with surge arresters on the market only provide Type 2, i.e., sudden overvoltage impulse protection. Meaning, lightning protection does not exist in these inverters. Moreover, due to the lack of Type 3 protection, the Up protection level of these surge arresters is high. Therefore, the protection of an electronic system such as an inverter cannot be achieved.<\/p>\n<p>As can be seen in the PV plant below, both AC and DC protection of the inverter is provided by using LV surge arresters before and after the inverter. It is important to perform Type 1 and Type 3 protection simultaneously to achieve this sensitive protection.<\/p>\n<figure id=\"attachment_5809\" aria-describedby=\"caption-attachment-5809\" style=\"width: 625px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/11\/inverter-koruma.jpg\"><img decoding=\"async\" class=\"wp-image-5809 size-full\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/11\/inverter-koruma.jpg\" alt=\"inverter-protection\" width=\"625\" height=\"380\" srcset=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/11\/inverter-koruma.jpg 625w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/11\/inverter-koruma-300x182.jpg 300w\" sizes=\"(max-width: 625px) 100vw, 625px\" \/><\/a><figcaption id=\"caption-attachment-5809\" class=\"wp-caption-text\">Protection of a PV plant with AC and DC surge arresters<\/figcaption><\/figure>\n<p>Another point not to be forgotten is that communication and measurement systems in solar power plants must be protected. From meteorological measuring devices such as radiation, wind, etc., to RS 232 communication lines, data collection systems must be protected. We have witnessed Data Loggers burning out in many SPP facilities in our country.<\/p>\n<blockquote>\n<p style=\"text-align: center;\"><em><strong>You May Be Interested In:<a href=\"https:\/\/yilkomer.com\/en\/protection-of-datalogger-systems-against-sudden-overvoltage\/\"> DataLogger Protection<\/a><\/strong><\/em><\/p>\n<\/blockquote>\n<\/div>\n<p><!-- .vgblk-rw-wrapper --><\/p>\n","protected":false},"excerpt":{"rendered":"<p>We observe that solar power plant investments are becoming more widespread in our country day by day. It is of great importance to protect these power plants, which are expected to operate efficiently for 20-25 years, from lightning and sudden overvoltage impulses. At this point, the correct selection of LV surge arrester systems can be&#8230;<\/p>\n","protected":false},"author":1,"featured_media":55365,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[],"tags":[],"class_list":["post-55363","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry"],"_links":{"self":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts\/55363","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/comments?post=55363"}],"version-history":[{"count":1,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts\/55363\/revisions"}],"predecessor-version":[{"id":994125,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts\/55363\/revisions\/994125"}],"wp:attachment":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/media?parent=55363"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/categories?post=55363"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/tags?post=55363"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}