{"id":54661,"date":"2016-08-14T10:02:54","date_gmt":"2016-08-14T07:02:54","guid":{"rendered":"https:\/\/yilkomer.com\/her-elektrik-muhendisinin-fabrikalarda-duzenli-olarak-yapmasi-gereken-5-olcum\/"},"modified":"2016-08-14T10:02:54","modified_gmt":"2016-08-14T07:02:54","slug":"5-measurements-every-electrical-engineer-must-regularly-perform-in-factories","status":"publish","type":"post","link":"https:\/\/yilkomer.com\/en\/5-measurements-every-electrical-engineer-must-regularly-perform-in-factories\/","title":{"rendered":"5 Measurements Every Electrical Engineer Must Regularly Perform in Factories"},"content":{"rendered":"<div class=\"vgblk-rw-wrapper limit-wrapper\">Regular <strong>measurements<\/strong> to be made in facilities are essential for the electrical continuity and safety of our facility. Indeed, in the inspections carried out by the <em><strong>Ministry of Labor<\/strong><\/em>, the electrical conformity of the facilities is inspected, and facilities that cannot pass these inspections receive penalties after a warning. Moreover, no room should be allowed for electrical errors in the facility so that uninterrupted and continuous production in factories is not interrupted. So, what are the measurements that a factory or facility should have done regularly?<\/p>\n<h2><a href=\"https:\/\/yilkomer.com\/en\/topraklama-olcumu\/\"><span style=\"color: #ff6600;\"><strong>1-Grounding Measurement<\/strong><\/span><\/a><\/h2>\n<p><strong>Grounding<\/strong> is one of the most important protection systems of a facility. Faults occurring in grounding put both life and property safety at risk. Grounding equipment and systems can deform, wear out, or even break over time. Therefore, factories need to perform grounding measurements regularly. Afterwards, it should be tested whether the protection equipment works correctly by taking the measurements into account. Again, care should be taken to ensure that <em>grounding values<\/em> remain below the determined values.<\/p>\n<figure id=\"attachment_4823\" aria-describedby=\"caption-attachment-4823\" style=\"width: 600px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/01\/topraklama-olcum-cihaz%C4%B1.jpg\"><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-4823 size-full\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/01\/topraklama-olcum-cihaz%C4%B1.jpg\" alt=\"grounding-measurement-device\" width=\"600\" height=\"402\" \/><\/a><figcaption id=\"caption-attachment-4823\" class=\"wp-caption-text\">We recommend that you have your grounding measurements done regularly.<\/figcaption><\/figure>\n<h3><span style=\"color: #ff6600;\"><strong>2-Residual Current Relay (RCD) Test<\/strong><\/span><\/h3>\n<p><a href=\"https:\/\/yilkomer.com\/en\/residual-current-device-rcd-measurement-test\/\"><strong>Residual current relays<\/strong> <\/a>are found in factories for 2 basic elements. There are 2 types: residual current relays that prevent fire and residual current relays that protect human health. However, in facilities such as factories, there are many machines with high inrush currents or high leakage current values. Or, residual current relays cannot fulfill their duty due to poor grounding. Therefore, tests of <em><strong>residual current relays<\/strong> <\/em>in the facility should be carried out regularly.<\/p>\n<figure id=\"attachment_4329\" aria-describedby=\"caption-attachment-4329\" style=\"width: 479px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/kacak-akim-rolesi-olcumu.jpg\"><img decoding=\"async\" class=\" wp-image-4329\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/kacak-akim-rolesi-olcumu.jpg\" alt=\"Residual current relay measurement is provided by our company.\" width=\"479\" height=\"387\" srcset=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/kacak-akim-rolesi-olcumu.jpg 1560w, https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/kacak-akim-rolesi-olcumu-300x242.jpg 300w, https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/kacak-akim-rolesi-olcumu-1024x827.jpg 1024w, https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/kacak-akim-rolesi-olcumu-768x620.jpg 768w, https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/kacak-akim-rolesi-olcumu-1536x1241.jpg 1536w\" sizes=\"(max-width: 479px) 100vw, 479px\" \/><\/a><figcaption id=\"caption-attachment-4329\" class=\"wp-caption-text\">Residual current relay measurement is provided by our company.<\/figcaption><\/figure>\n<p><span style=\"color: #ff6600;\"><strong>3-External Lightning Protection Measurement<\/strong><\/span><\/p>\n<p><span style=\"color: #ff6600;\"><strong>External lightning protection<\/strong><\/span> systems are equipment that provide physical protection against lightning. Deformation and corrosion occurring over time cause the grounding values of external lightning protection systems to increase. This causes effective protection against incoming lightning impulses not to be achieved. Every facility should have its external lightning protection systems tested and maintained regularly.<\/p>\n<figure id=\"attachment_5604\" aria-describedby=\"caption-attachment-5604\" style=\"width: 600px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/08\/d%C4%B1%C5%9F-y%C4%B1ld%C4%B1r%C4%B1ml%C4%B1k-bak%C4%B1m%C4%B1.jpg\"><img decoding=\"async\" class=\"wp-image-5604 size-full\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/08\/d%C4%B1%C5%9F-y%C4%B1ld%C4%B1r%C4%B1ml%C4%B1k-bak%C4%B1m%C4%B1.jpg\" alt=\"external-lightning-protection-maintenance\" width=\"600\" height=\"338\" \/><\/a><figcaption id=\"caption-attachment-5604\" class=\"wp-caption-text\">Have the maintenance of external lightning protection systems done regularly<\/figcaption><\/figure>\n<p><span style=\"color: #ff6600;\"><strong>4-Thermal Measurement and Insulation Resistance Measurement<\/strong><\/span><\/p>\n<p>In ensuring the electrical safety of a factory, insulation systems must be in good condition and error-free. Thermal measurement and insulation resistance measurement provide important clues in pre-determining the electrical problems of systems such as motors, cables, and main switches. These 2 measurements must be made in the realization of preventive maintenance.<\/p>\n<figure id=\"attachment_5112\" aria-describedby=\"caption-attachment-5112\" style=\"width: 437px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/03\/termal-%C3%B6l%C3%A7%C3%BCm-kontrol%C3%BC.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\" wp-image-5112\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/03\/termal-%C3%B6l%C3%A7%C3%BCm-kontrol%C3%BC.jpg\" alt=\"Faults can be easily detected by performing thermal measurement in panels.\" width=\"437\" height=\"421\" \/><\/a><figcaption id=\"caption-attachment-5112\" class=\"wp-caption-text\">Faults can be easily detected by performing thermal measurement in panels.<\/figcaption><\/figure>\n<p><span style=\"color: #ff6600;\"><strong>5-Harmonic Measurement<\/strong><\/span><\/p>\n<p>Harmonics started to form strongly in electrical networks with the increase of semiconductor elements. Due to harmonics, the quality of the power grid decreases and devices in facilities can be damaged. Moreover, there can be serious decreases in energy efficiency due to harmonics, and this situation can be reflected in the factory. Facilities need to measure whether their total <strong>harmonic<\/strong> distortions are within legal limits and use filters if necessary.<\/div>\n<p><!-- .vgblk-rw-wrapper --><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Regular measurements to be made in facilities are essential for the electrical continuity and safety of our facility. Indeed, in the inspections carried out by the Ministry of Labor, the electrical conformity of the facilities is inspected, and facilities that cannot pass these inspections receive penalties after a warning. Moreover, no room should be allowed&#8230;<\/p>\n","protected":false},"author":1,"featured_media":53748,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[],"tags":[],"class_list":["post-54661","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry"],"_links":{"self":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts\/54661","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/comments?post=54661"}],"version-history":[{"count":0,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts\/54661\/revisions"}],"wp:attachment":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/media?parent=54661"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/categories?post=54661"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/tags?post=54661"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}