{"id":54300,"date":"2016-07-30T06:33:00","date_gmt":"2016-07-30T03:33:00","guid":{"rendered":"https:\/\/yilkomer.com\/ex-proof-yalitimli-yildirim-inis-iletkeni\/"},"modified":"2026-01-11T21:32:56","modified_gmt":"2026-01-11T18:32:56","slug":"ex-proof-insulated-isolated-lightning-down-conductor","status":"publish","type":"post","link":"https:\/\/yilkomer.com\/en\/ex-proof-insulated-isolated-lightning-down-conductor\/","title":{"rendered":"Ex-Proof Insulated (Isolated) Lightning Down Conductor"},"content":{"rendered":"<p>As Y\u0131lkomer, as a result of our long-standing efforts, the concept of insulated lightning protection systems has gradually begun to be established in our country. However, the insulated lightning protection system that we try to explain within the scope of <strong>IEC standards<\/strong> has started to be understood and implemented in our country merely as connecting a medium-voltage cable to a lightning rod system. Unfortunately, over time, every subject in our country turns into a commercial matter, and we consistently move away from technical principles. As <span style=\"color: #ff6600;\"><strong>Y\u0131lkomer<\/strong> <\/span>, we wanted to explain the insulated <em><span style=\"color: #ff6600;\"><strong><a style=\"color: #ff6600;\" href=\"https:\/\/yilkomer.com\/en\/lightning-air-terminal-franklin-rod\/\">lightning air terminal<\/a><\/strong><\/span><\/em> system to you once again. This subject is an extremely important technical matter that directly concerns life and property safety, especially for flammable and explosive areas, and has the capability to eliminate fire risks and electrical system damage.<\/p>\n<p>First of all, this subject must be addressed as a \u201cSYSTEM\u201d. If lightning air terminals to which the insulated conductor is connected are used on metallic surfaces, they must be insulated. Moreover, the separation distances must have fully insulating properties and must not be less than 1500 mm. The insulated conductor must be mounted internally within the air terminal so that surface contact is eliminated when an impulse occurs. The insulated conductor must be grounded to a metallic surface both inside the air terminal and along the entire route. Fundamentally, the steps can be listed in this manner.<\/p>\n<div id=\"attachment_5456\" style=\"width: 478px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/izole-kullan\u0131m\u0131.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-5456\" class=\"wp-image-5456\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/izole-kullan\u0131m\u0131.jpg\" alt=\"izole-kullan\u0131m\u0131\" width=\"468\" height=\"263\" srcset=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/izole-kullan\u0131m\u0131.jpg 1200w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/izole-kullan\u0131m\u0131-300x169.jpg 300w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/izole-kullan\u0131m\u0131-1024x576.jpg 1024w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/izole-kullan\u0131m\u0131-768x432.jpg 768w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/izole-kullan\u0131m\u0131-260x146.jpg 260w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/izole-kullan\u0131m\u0131-50x28.jpg 50w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/izole-kullan\u0131m\u0131-133x75.jpg 133w\" sizes=\"auto, (max-width:767px) 468px, 468px\" \/><\/a><p id=\"caption-attachment-5456\" class=\"wp-caption-text\">Use of insulated lightning down conductor<\/p><\/div>\n<p>Primarily, the kiloampere-based test value of the insulated lightning down conductor is of critical importance. This value, ranging between 150 kA and 200 kA, must have <strong>200 kA withstand capability<\/strong> for explosive environments. The <strong><span style=\"text-decoration: underline;\">S separation distance<\/span><\/strong> mentioned for lightning down conductors is also valid for insulated down conductors in explosive environments. For this reason, special conductors that ensure the required \u201cS\u201d separation distance are manufactured. Especially in flammable and explosive areas, each manufacturer must specify the \u201cS\u201d distance of the cable. This distance generally appears at the level of 0.75 or 0.50 cm and is of great importance. For magnetic field protection, direct mounting to the wall does not pose a problem. In addition, manufacturers have determined the maximum usable height of the insulated conductor through testing. As practiced in our country, performing unlimited down-conduction on a 100-meter building using insulated conductors is not an appropriate application.<\/p>\n<div id=\"attachment_5457\" style=\"width: 787px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/binalarda-izoleli-y\u0131ld\u0131r\u0131m-iletkeni.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-5457\" class=\"wp-image-5457 size-full\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/binalarda-izoleli-y\u0131ld\u0131r\u0131m-iletkeni.jpg\" alt=\"binalarda-izoleli-y\u0131ld\u0131r\u0131m-iletkeni\" width=\"777\" height=\"364\" srcset=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/binalarda-izoleli-y\u0131ld\u0131r\u0131m-iletkeni.jpg 777w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/binalarda-izoleli-y\u0131ld\u0131r\u0131m-iletkeni-300x141.jpg 300w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/binalarda-izoleli-y\u0131ld\u0131r\u0131m-iletkeni-768x360.jpg 768w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/binalarda-izoleli-y\u0131ld\u0131r\u0131m-iletkeni-260x122.jpg 260w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/binalarda-izoleli-y\u0131ld\u0131r\u0131m-iletkeni-50x23.jpg 50w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/binalarda-izoleli-y\u0131ld\u0131r\u0131m-iletkeni-150x70.jpg 150w\" sizes=\"auto, (max-width:767px) 480px, (max-width:777px) 100vw, 777px\" \/><\/a><p id=\"caption-attachment-5457\" class=\"wp-caption-text\">Insulated conductors should also be used in building and roof applications.<\/p><\/div>\n<p>As Y\u0131lkomer, we use HVI series products manufactured in Germany. We use two models, Long and Power, in our systems together with the insulated lightning air terminal system. In particular, the HVI Power insulated down conductor system can be described as the safest insulated down conductor system due to its 200 kA withstand capability and EX environment certification. The most important point in these matters is product certification and testability. Manufacturers should emphasize the withstand capacities and ex-proof characteristics of insulated systems in the declarations they publish.<\/p>\n<div id=\"attachment_5458\" style=\"width: 650px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/biyogaz-tesis.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-5458\" class=\"wp-image-5458 size-full\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/biyogaz-tesis.jpg\" alt=\"biyogaz-tesis\" width=\"640\" height=\"360\" srcset=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/biyogaz-tesis.jpg 640w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/biyogaz-tesis-300x169.jpg 300w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/biyogaz-tesis-260x146.jpg 260w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/biyogaz-tesis-50x28.jpg 50w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/biyogaz-tesis-133x75.jpg 133w\" sizes=\"auto, (max-width:767px) 480px, 640px\" \/><\/a><p id=\"caption-attachment-5458\" class=\"wp-caption-text\">Insulated lightning down conductors should also be used in explosive facilities.<\/p><\/div>\n<blockquote>\n<p style=\"text-align: center;\">In conclusion, the Insulated Lightning Protection System requires a design consisting of system components.<\/p>\n<\/blockquote>\n<ul>\n<li>First, the insulated conductor should be selected according to the characteristics of the area of use.<\/li>\n<li>The lightning air terminal system must be insulated, especially on metallic surfaces, and the conductor must pass internally.<\/li>\n<li>Insulated conductor holders should be selected as ex-proof and with S separation distance according to the protection zone classification.<\/li>\n<li>The conductor surface must be grounded.<\/li>\n<\/ul>\n<div id=\"attachment_5459\" style=\"width: 378px\" class=\"wp-caption alignleft\"><a href=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/ges-y\u0131ld\u0131r\u0131m-ini\u015f.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-5459\" class=\"wp-image-5459 size-full\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/ges-y\u0131ld\u0131r\u0131m-ini\u015f.jpg\" alt=\"ges-y\u0131ld\u0131r\u0131m-ini\u015f\" width=\"368\" height=\"207\" srcset=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/ges-y\u0131ld\u0131r\u0131m-ini\u015f.jpg 368w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/ges-y\u0131ld\u0131r\u0131m-ini\u015f-300x169.jpg 300w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/ges-y\u0131ld\u0131r\u0131m-ini\u015f-260x146.jpg 260w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/ges-y\u0131ld\u0131r\u0131m-ini\u015f-50x28.jpg 50w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/ges-y\u0131ld\u0131r\u0131m-ini\u015f-133x75.jpg 133w\" sizes=\"auto, (max-width:767px) 368px, 368px\" \/><\/a><p id=\"caption-attachment-5459\" class=\"wp-caption-text\">Passive air terminals and insulated conductors should also be used together in solar power plants (GES).<\/p><\/div>\n<ul>\n<li>The conductor must be grounded within the air terminal, and the insulated area of the air terminal must be at least 1500 mm.<\/li>\n<li>The conductor cannot be routed down the building with unlimited length; impedance losses must be calculated.<\/li>\n<li>The conductor must have suitability certificates for use in Zone 1 and Zone 2.<\/li>\n<li>The insulated down conductor system must be bonded to equipotential at the end of the down conductor. Equipotential bonding can be performed using <strong>spark gap arresters<\/strong>; in ex areas, spark gap arresters must also be selected as ex-proof.<\/li>\n<li>All system components used in the installation must also have a 200 kA test certificate.<\/li>\n<\/ul>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>As Y\u0131lkomer, as a result of our long-standing efforts, the concept of insulated lightning protection systems has gradually begun to be established in our country. However,<span class=\"excerpt-hellip\"> [\u2026]<\/span><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_joinchat":[],"footnotes":""},"categories":[193],"tags":[],"class_list":["post-54300","post","type-post","status-publish","format-standard","hentry","category-general"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v19.2.1 (Yoast SEO v27.5) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Ex-Proof Insulated (Isolated) Lightning Down Conductor<\/title>\n<meta name=\"description\" content=\"As Y\u0131lkomer, we wanted to explain the insulated lightning air terminal system to you once again. The subject concerns life and property safety, flammable and explosive\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/yilkomer.com\/en\/ex-proof-insulated-isolated-lightning-down-conductor\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Ex-Proof Insulated (Isolated) Lightning Down Conductor\" \/>\n<meta property=\"og:description\" content=\"As Y\u0131lkomer, as a result of our long-standing efforts, the concept of insulated lightning protection systems has gradually begun to be established in our\" \/>\n<meta property=\"og:url\" content=\"https:\/\/yilkomer.com\/en\/ex-proof-insulated-isolated-lightning-down-conductor\/\" \/>\n<meta property=\"og:site_name\" content=\"Y\u0131lkomer\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/yilkomer\" \/>\n<meta property=\"article:published_time\" content=\"2016-07-30T03:33:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-01-11T18:32:56+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/izole-kullan\u0131m\u0131.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"1200\" \/>\n\t<meta property=\"og:image:height\" content=\"675\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"6 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/ex-proof-insulated-isolated-lightning-down-conductor\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/ex-proof-insulated-isolated-lightning-down-conductor\\\/\"},\"author\":{\"name\":\"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#\\\/schema\\\/person\\\/1378732ec91a59af36092fedd9f6f871\"},\"headline\":\"Ex-Proof Insulated (Isolated) Lightning Down Conductor\",\"datePublished\":\"2016-07-30T03:33:00+00:00\",\"dateModified\":\"2026-01-11T18:32:56+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/ex-proof-insulated-isolated-lightning-down-conductor\\\/\"},\"wordCount\":716,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/ex-proof-insulated-isolated-lightning-down-conductor\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/yilkomer.com\\\/wp-content\\\/uploads\\\/2016\\\/05\\\/biyogaz-tesis.jpg\",\"articleSection\":[\"General\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/yilkomer.com\\\/en\\\/ex-proof-insulated-isolated-lightning-down-conductor\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/ex-proof-insulated-isolated-lightning-down-conductor\\\/\",\"url\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/ex-proof-insulated-isolated-lightning-down-conductor\\\/\",\"name\":\"Ex-Proof Insulated (Isolated) Lightning Down Conductor\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/ex-proof-insulated-isolated-lightning-down-conductor\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/ex-proof-insulated-isolated-lightning-down-conductor\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/yilkomer.com\\\/wp-content\\\/uploads\\\/2016\\\/05\\\/biyogaz-tesis.jpg\",\"datePublished\":\"2016-07-30T03:33:00+00:00\",\"dateModified\":\"2026-01-11T18:32:56+00:00\",\"description\":\"As Y\u0131lkomer, we wanted to explain the insulated lightning air terminal system to you once again. The subject concerns life and property safety, flammable and explosive\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/ex-proof-insulated-isolated-lightning-down-conductor\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/yilkomer.com\\\/en\\\/ex-proof-insulated-isolated-lightning-down-conductor\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/ex-proof-insulated-isolated-lightning-down-conductor\\\/#primaryimage\",\"url\":\"https:\\\/\\\/yilkomer.com\\\/wp-content\\\/uploads\\\/2016\\\/05\\\/biyogaz-tesis.jpg\",\"contentUrl\":\"https:\\\/\\\/yilkomer.com\\\/wp-content\\\/uploads\\\/2016\\\/05\\\/biyogaz-tesis.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/ex-proof-insulated-isolated-lightning-down-conductor\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Ana Sayfa\",\"item\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Ex-Proof Insulated (Isolated) Lightning Down Conductor\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/\",\"name\":\"Y\u0131lkomer\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#organization\"},\"alternateName\":\"Y\u0131lkomer\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#organization\",\"name\":\"Yilkomer\",\"url\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/yilkomer.com\\\/wp-content\\\/uploads\\\/2015\\\/01\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/yilkomer.com\\\/wp-content\\\/uploads\\\/2015\\\/01\\\/logo.png\",\"width\":1000,\"height\":189,\"caption\":\"Yilkomer\"},\"image\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#\\\/schema\\\/person\\\/1378732ec91a59af36092fedd9f6f871\",\"name\":\"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi\",\"description\":\"Y\u0131lkomer (Y\u0131ld\u0131r\u0131mdan Korunma Merkezi) \u00fclkemizde y\u0131ld\u0131r\u0131mdan ve a\u015f\u0131r\u0131 gerilimden korunmada teknik eksiklikleri ortadan kald\u0131rarak tamamen standartlar ve m\u00fchendislik hesaplar\u0131na dayanarak sistem kurmay\u0131 hedeflemektedir.\",\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/yilkomer\",\"https:\\\/\\\/www.linkedin.com\\\/profile\\\/view?id=393173773&trk=nav_responsive_tab_profile\",\"https:\\\/\\\/x.com\\\/https:\\\/\\\/twitter.com\\\/yilkomer\",\"admin\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Ex-Proof Insulated (Isolated) Lightning Down Conductor","description":"As Y\u0131lkomer, we wanted to explain the insulated lightning air terminal system to you once again. The subject concerns life and property safety, flammable and explosive","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/yilkomer.com\/en\/ex-proof-insulated-isolated-lightning-down-conductor\/","og_locale":"en_US","og_type":"article","og_title":"Ex-Proof Insulated (Isolated) Lightning Down Conductor","og_description":"As Y\u0131lkomer, as a result of our long-standing efforts, the concept of insulated lightning protection systems has gradually begun to be established in our","og_url":"https:\/\/yilkomer.com\/en\/ex-proof-insulated-isolated-lightning-down-conductor\/","og_site_name":"Y\u0131lkomer","article_author":"https:\/\/www.facebook.com\/yilkomer","article_published_time":"2016-07-30T03:33:00+00:00","article_modified_time":"2026-01-11T18:32:56+00:00","og_image":[{"width":1200,"height":675,"url":"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/izole-kullan\u0131m\u0131.jpg","type":"image\/jpeg"}],"author":"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi","twitter_misc":{"Written by":"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi","Est. reading time":"6 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/yilkomer.com\/en\/ex-proof-insulated-isolated-lightning-down-conductor\/#article","isPartOf":{"@id":"https:\/\/yilkomer.com\/en\/ex-proof-insulated-isolated-lightning-down-conductor\/"},"author":{"name":"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi","@id":"https:\/\/yilkomer.com\/en\/#\/schema\/person\/1378732ec91a59af36092fedd9f6f871"},"headline":"Ex-Proof Insulated (Isolated) Lightning Down Conductor","datePublished":"2016-07-30T03:33:00+00:00","dateModified":"2026-01-11T18:32:56+00:00","mainEntityOfPage":{"@id":"https:\/\/yilkomer.com\/en\/ex-proof-insulated-isolated-lightning-down-conductor\/"},"wordCount":716,"commentCount":0,"publisher":{"@id":"https:\/\/yilkomer.com\/en\/#organization"},"image":{"@id":"https:\/\/yilkomer.com\/en\/ex-proof-insulated-isolated-lightning-down-conductor\/#primaryimage"},"thumbnailUrl":"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/biyogaz-tesis.jpg","articleSection":["General"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/yilkomer.com\/en\/ex-proof-insulated-isolated-lightning-down-conductor\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/yilkomer.com\/en\/ex-proof-insulated-isolated-lightning-down-conductor\/","url":"https:\/\/yilkomer.com\/en\/ex-proof-insulated-isolated-lightning-down-conductor\/","name":"Ex-Proof Insulated (Isolated) Lightning Down Conductor","isPartOf":{"@id":"https:\/\/yilkomer.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/yilkomer.com\/en\/ex-proof-insulated-isolated-lightning-down-conductor\/#primaryimage"},"image":{"@id":"https:\/\/yilkomer.com\/en\/ex-proof-insulated-isolated-lightning-down-conductor\/#primaryimage"},"thumbnailUrl":"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/biyogaz-tesis.jpg","datePublished":"2016-07-30T03:33:00+00:00","dateModified":"2026-01-11T18:32:56+00:00","description":"As Y\u0131lkomer, we wanted to explain the insulated lightning air terminal system to you once again. The subject concerns life and property safety, flammable and explosive","breadcrumb":{"@id":"https:\/\/yilkomer.com\/en\/ex-proof-insulated-isolated-lightning-down-conductor\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/yilkomer.com\/en\/ex-proof-insulated-isolated-lightning-down-conductor\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/yilkomer.com\/en\/ex-proof-insulated-isolated-lightning-down-conductor\/#primaryimage","url":"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/biyogaz-tesis.jpg","contentUrl":"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/biyogaz-tesis.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/yilkomer.com\/en\/ex-proof-insulated-isolated-lightning-down-conductor\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Ana Sayfa","item":"https:\/\/yilkomer.com\/en\/"},{"@type":"ListItem","position":2,"name":"Ex-Proof Insulated (Isolated) Lightning Down Conductor"}]},{"@type":"WebSite","@id":"https:\/\/yilkomer.com\/en\/#website","url":"https:\/\/yilkomer.com\/en\/","name":"Y\u0131lkomer","description":"","publisher":{"@id":"https:\/\/yilkomer.com\/en\/#organization"},"alternateName":"Y\u0131lkomer","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/yilkomer.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/yilkomer.com\/en\/#organization","name":"Yilkomer","url":"https:\/\/yilkomer.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/yilkomer.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/01\/logo.png","contentUrl":"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/01\/logo.png","width":1000,"height":189,"caption":"Yilkomer"},"image":{"@id":"https:\/\/yilkomer.com\/en\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/yilkomer.com\/en\/#\/schema\/person\/1378732ec91a59af36092fedd9f6f871","name":"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi","description":"Y\u0131lkomer (Y\u0131ld\u0131r\u0131mdan Korunma Merkezi) \u00fclkemizde y\u0131ld\u0131r\u0131mdan ve a\u015f\u0131r\u0131 gerilimden korunmada teknik eksiklikleri ortadan kald\u0131rarak tamamen standartlar ve m\u00fchendislik hesaplar\u0131na dayanarak sistem kurmay\u0131 hedeflemektedir.","sameAs":["https:\/\/www.facebook.com\/yilkomer","https:\/\/www.linkedin.com\/profile\/view?id=393173773&trk=nav_responsive_tab_profile","https:\/\/x.com\/https:\/\/twitter.com\/yilkomer","admin"]}]}},"_links":{"self":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts\/54300","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/comments?post=54300"}],"version-history":[{"count":2,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts\/54300\/revisions"}],"predecessor-version":[{"id":54317,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts\/54300\/revisions\/54317"}],"wp:attachment":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/media?parent=54300"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/categories?post=54300"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/tags?post=54300"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}