{"id":53878,"date":"2016-05-07T14:53:36","date_gmt":"2016-05-07T11:53:36","guid":{"rendered":"https:\/\/yilkomer.com\/plclerin-asiri-gerilimden-korunmasi\/"},"modified":"2026-08-22T18:09:45","modified_gmt":"2026-08-22T15:09:45","slug":"protection-of-plcs-against-overvoltage","status":"publish","type":"post","link":"https:\/\/yilkomer.com\/en\/protection-of-plcs-against-overvoltage\/","title":{"rendered":"Protection of PLCs Against Overvoltage"},"content":{"rendered":"<div class=\"vgblk-rw-wrapper limit-wrapper\">PLC systems are the heart of an automation system. From factories to airports, PLCs perform critical tasks across a wide range of applications. Similarly, RTU and SCADA systems are fundamental components of an automation system. As Y\u0131lkomer, we have witnessed production halting in many factories when a PLC or RTU goes offline. These highly sensitive systems must be protected starting with main panel protection and finishing with a precise protection placed directly in front of the PLC.<\/p>\n<blockquote>\n<p style=\"text-align: center;\"><strong>You may also be interested in: <a href=\"https:\/\/yilkomer.com\/ag-parafudr\/\">AG Surge Protectors<\/a><\/strong><\/p>\n<\/blockquote>\n<h2><span style=\"color: #ff6600;\">Concept of Up<\/span><\/h2>\n<p>When protecting sensitive systems like PLC, RTU, and SCADA, it is essential to understand the concept of Up protection level. The Up level is the voltage that the surge protector can reduce the incoming surge to. The values differ for products used in main and sub panels. The lower the Up value of a surge protector, the more sensitive the protection. However, as In and Imax values increase, the Up level also rises. Therefore, the main panel, sub panels, and finally D-class surge protectors reduce the surge to a level that will not damage the target device. Protecting only the main or sub panels is not sufficient to achieve the desired Up level.<\/p>\n<h3><strong><span style=\"color: #ff6600;\">Protection of Analog or Digital Input\/Output (IO)<\/span><\/strong><\/h3>\n<p>These systems usually operate at 24 V with currents below 250 mA. Protection is applied using a D-class surge protector connected in series. Systems operating between 5V\u2013110 V can be safely protected.<\/p>\n<figure id=\"attachment_5350\" aria-describedby=\"caption-attachment-5350\" style=\"width: 670px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/plc-24v.jpg\"><img fetchpriority=\"high\" decoding=\"async\" class=\"size-full wp-image-5350\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/plc-24v.jpg\" alt=\"PLC 24 V protection\" width=\"670\" height=\"314\" srcset=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/plc-24v.jpg 670w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/plc-24v-300x141.jpg 300w\" sizes=\"(max-width: 670px) 100vw, 670px\" \/><\/a><figcaption id=\"caption-attachment-5350\" class=\"wp-caption-text\">PLC 24 V protection<\/figcaption><\/figure>\n<p><span style=\"color: #ff6600;\"><strong>Systems up to 6 Amps<\/strong><\/span><\/p>\n<p>For systems with currents higher than 250 mA, different surge protectors are used. The connection scheme is the same as previously described.<\/p>\n<p><a href=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/6a-parafudr.jpg\"><img decoding=\"async\" class=\"size-full wp-image-5351 aligncenter\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/6a-parafudr.jpg\" alt=\"6a-surge-protector\" width=\"824\" height=\"444\" srcset=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/6a-parafudr.jpg 824w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/6a-parafudr-300x162.jpg 300w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/6a-parafudr-768x414.jpg 768w\" sizes=\"(max-width: 824px) 100vw, 824px\" \/><\/a><\/p>\n<h4><span style=\"color: #ff6600;\"><strong>4-20 mA Protection<\/strong><\/span><\/h4>\n<p>Another common system in factories is the 4-20 mA loop. The loop is protected with a surge protector, and the LED status indicates both loop and protector status.<\/p>\n<p><a href=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/4-20-ma.jpg\"><img decoding=\"async\" class=\"size-full wp-image-5352 aligncenter\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/4-20-ma.jpg\" alt=\"4-20 mA\" width=\"858\" height=\"436\" srcset=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/4-20-ma.jpg 858w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/4-20-ma-300x152.jpg 300w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/4-20-ma-768x390.jpg 768w\" sizes=\"(max-width: 858px) 100vw, 858px\" \/><\/a><\/p>\n<p><span style=\"color: #ff6600;\"><strong>RS232-RS485 and RS-422 Overvoltage Protection<\/strong><\/span><\/p>\n<p><span style=\"text-decoration: underline;\"><em><strong>RS232, RS485, and RS-422<\/strong><\/em><\/span> are high-speed IO lines. The selected <em><strong>surge protector<\/strong><\/em> must be compatible with the required frequency range. Profibus and Modbus lines are protected similarly.<\/p>\n<p><em><span style=\"color: #ff6600;\"><strong>RS232 Protection<\/strong><\/span><\/em><\/p>\n<p>RS232 line protection can be seen in the following diagram:<\/p>\n<p><a href=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/rs232-koruma.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-5353 aligncenter\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/rs232-koruma.jpg\" alt=\"rs232-protection\" width=\"938\" height=\"398\" srcset=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/rs232-koruma.jpg 938w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/rs232-koruma-300x127.jpg 300w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/rs232-koruma-768x326.jpg 768w\" sizes=\"(max-width: 938px) 100vw, 938px\" \/><\/a><\/p>\n<p><span style=\"color: #ff6600;\"><em><strong>RS485 Protection<\/strong><\/em><\/span><\/p>\n<p>Point-to-point RS-485 line protection is shown in the diagram below:<\/p>\n<p><a href=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/rs-485-koruma.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-5354 aligncenter\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/rs-485-koruma.jpg\" alt=\"rs-485-protection\" width=\"900\" height=\"400\" srcset=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/rs-485-koruma.jpg 900w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/rs-485-koruma-300x133.jpg 300w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/05\/rs-485-koruma-768x341.jpg 768w\" sizes=\"(max-width: 900px) 100vw, 900px\" \/><\/a><\/p>\n<p><strong>PLC systems<\/strong> can also be protected during installation by using terminal block surge protectors. Preference for <span style=\"color: #ff6600;\"><strong>terminal block surge protectors<\/strong><\/span> is common in many applications. The images show examples of terminal block type protectors. PLC systems can be protected during installation, or if not previously protected, a site inspection can determine the correct products for retrofitting. For protection against lightning and <span style=\"text-decoration: underline;\"><strong>sudden overvoltage surges<\/strong><\/span>, you can contact <a href=\"https:\/\/yilkomer.com\/en\/\"><strong>Y\u0131lkomer<\/strong><\/a>.<\/p>\n<figure id=\"attachment_4746\" aria-describedby=\"caption-attachment-4746\" style=\"width: 650px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/12\/24-v-koruma.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-4746\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/12\/24-v-koruma.jpg\" alt=\"Terminal block surge protectors used for sensitive systems\" width=\"650\" height=\"559\" srcset=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/12\/24-v-koruma.jpg 650w, https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/12\/24-v-koruma-300x258.jpg 300w\" sizes=\"(max-width: 650px) 100vw, 650px\" \/><\/a><figcaption id=\"caption-attachment-4746\" class=\"wp-caption-text\">Terminal block surge protectors used for protecting sensitive systems<\/figcaption><\/figure>\n<p>&nbsp;<\/p><\/div>\n<p><!-- .vgblk-rw-wrapper --><\/p>\n","protected":false},"excerpt":{"rendered":"<p>PLC systems are the heart of an automation system. From factories to airports, PLCs perform critical tasks across a wide range of applications. Similarly, RTU and SCADA systems are fundamental components of an automation system. As Y\u0131lkomer, we have witnessed production halting in many factories when a PLC or RTU goes offline. These highly sensitive&#8230;<\/p>\n","protected":false},"author":1,"featured_media":53880,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[],"tags":[],"class_list":["post-53878","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry"],"_links":{"self":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts\/53878","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/comments?post=53878"}],"version-history":[{"count":1,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts\/53878\/revisions"}],"predecessor-version":[{"id":994144,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts\/53878\/revisions\/994144"}],"wp:attachment":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/media?parent=53878"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/categories?post=53878"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/tags?post=53878"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}