{"id":53735,"date":"2016-03-15T14:04:17","date_gmt":"2016-03-15T12:04:17","guid":{"rendered":"https:\/\/yilkomer.com\/elektrik-ic-tesisat-kontrolu\/"},"modified":"2025-12-20T00:28:21","modified_gmt":"2025-12-19T21:28:21","slug":"electrical-internal-installation-inspection","status":"publish","type":"post","link":"https:\/\/yilkomer.com\/en\/electrical-internal-installation-inspection\/","title":{"rendered":"Electrical Internal Installation Inspection"},"content":{"rendered":"<p>Industrial Maintenance refers to all interventions that minimize equipment failures in the field, extend their service life, and ensure the continuity of the enterprise\u2019s established operations. Considering the conditions required by the industrial environment and the equipment operating under these conditions, it is likely that such equipment may cause faults and reach the end of their service life. Therefore, preventing or reducing equipment failures, replacing equipment that has reached the end of its life, and ensuring efficient use of equipment throughout its operational life are only possible through maintenance. <em><strong>Electrical internal installations<\/strong><\/em> may age over time, experience connection problems, or lose functionality. For this reason, electrical internal installations should be checked regularly. In accordance with occupational safety and relevant regulations, electrical installations should be inspected regularly <em><strong>every year<\/strong><\/em>. In addition to ensuring business continuity, industrial maintenance provides significant benefits to enterprises.<\/p>\n<p style=\"text-align: center;\">You May Be Interested In: <strong><a href=\"https:\/\/yilkomer.com\/topraklama-olcum-periyotlari\/\" target=\"_blank\" rel=\"noopener\">Grounding Measurement Periods<\/a><\/strong><\/p>\n<ul>\n<li>Prevents unplanned downtime.<\/li>\n<li>Prevents high energy losses. (Increases energy efficiency)<\/li>\n<li>Reduces personnel injuries. (Ensures occupational safety)<\/li>\n<li>Prevents quality deterioration in production caused by disruptions, failures, or collapses<\/li>\n<\/ul>\n<p style=\"text-align: center;\"><strong><em>So, what should be checked during an internal installation inspection?<\/em><\/strong><\/p>\n<ul>\n<li>Main Panels and Sub Panels<\/li>\n<li><span style=\"color: #ff6600;\"><strong>External Lightning Protection and Lightning Protection Equipment<\/strong><\/span><\/li>\n<li>Machines, Generators, and Motors<\/li>\n<li>Sockets and Boxes<\/li>\n<li>Energy Cables<\/li>\n<li><span style=\"color: #ff6600;\"><strong><a href=\"https:\/\/yilkomer.com\/en\/topraklama-olcumu\/\" target=\"_blank\" rel=\"noopener\">Grounding measurements and inspections<\/a><\/strong><\/span><\/li>\n<li>Lighting systems<\/li>\n<li>Equipotential inspection<\/li>\n<li>Fuse, switch, and residual current device inspection<\/li>\n<li>Harmonic inspection<\/li>\n<li>Compliance of electrical hazard and warning signs<\/li>\n<li>Compliance of the electrical labeling system<\/li>\n<\/ul>\n<h2><span style=\"color: #ff6600;\"><strong>Internal Installation Inspection and Thermal Measurement<\/strong><\/span><\/h2>\n<p>Thermal imaging in electrical and mechanical installations provides important clues about system health. When a fault occurs in panels, cables, or electric motors, the relevant section overheats. When measurements are taken with a <strong>thermal camera<\/strong>, faulty areas can be easily identified.<\/p>\n<div id=\"attachment_5112\" style=\"width: 585px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/03\/termal-\u00f6l\u00e7\u00fcm-kontrol\u00fc.jpg\" rel=\"attachment wp-att-5112\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-5112\" class=\" wp-image-5112\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/03\/termal-\u00f6l\u00e7\u00fcm-kontrol\u00fc.jpg\" alt=\"Panolarda Termal \u00f6l\u00e7\u00fcm ger\u00e7ekle\u015ftirilerek kolayl\u0131kla hatalar tespit edilebilir.\" width=\"575\" height=\"554\" srcset=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/03\/termal-\u00f6l\u00e7\u00fcm-kontrol\u00fc.jpg 700w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/03\/termal-\u00f6l\u00e7\u00fcm-kontrol\u00fc-300x289.jpg 300w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/03\/termal-\u00f6l\u00e7\u00fcm-kontrol\u00fc-151x146.jpg 151w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/03\/termal-\u00f6l\u00e7\u00fcm-kontrol\u00fc-50x48.jpg 50w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/03\/termal-\u00f6l\u00e7\u00fcm-kontrol\u00fc-78x75.jpg 78w\" sizes=\"auto, (max-width:767px) 480px, 575px\" \/><\/a><p id=\"caption-attachment-5112\" class=\"wp-caption-text\">Faults can be easily detected by performing thermal measurements on panels.<\/p><\/div>\n<p>Thanks to thermal measurement, electrical connection faults and conductor defects can be easily detected. On the other hand, electrical motors heat up due to faults occurring within them. Electrical impulses can cause stator faults for many reasons, including dielectric effects, looseness, transient voltage conditions, and corona. Dielectric materials used between phase-ground, winding-winding, and phase-phase may cause insulation faults under voltage stress. Therefore, high-class insulation materials should be selected. Transient voltage changes show their effects over many years. These transient effects include lightning impulses, voltage fluctuations caused by drives, rapid busbar changes, circuit breaker switching operations, and capacitor switching. These transient effects gradually deteriorate insulation, eventually causing winding-to-winding, phase-to-ground, and winding-to-ground faults.<\/p>\n<div id=\"attachment_5113\" style=\"width: 650px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/03\/elektrik-motorlar\u0131nda-termal-\u00f6l\u00e7\u00fcm.jpg\" rel=\"attachment wp-att-5113\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-5113\" class=\" wp-image-5113\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/03\/elektrik-motorlar\u0131nda-termal-\u00f6l\u00e7\u00fcm.jpg\" alt=\"Elektrik motorlar\u0131nda termal \u00f6l\u00e7\u00fcm yap\u0131larak enerji verimlili\u011finin \u00f6n\u00fcne ge\u00e7en hatalar tespit edilir.\" width=\"640\" height=\"479\" srcset=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/03\/elektrik-motorlar\u0131nda-termal-\u00f6l\u00e7\u00fcm.jpg 701w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/03\/elektrik-motorlar\u0131nda-termal-\u00f6l\u00e7\u00fcm-300x225.jpg 300w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/03\/elektrik-motorlar\u0131nda-termal-\u00f6l\u00e7\u00fcm-195x146.jpg 195w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/03\/elektrik-motorlar\u0131nda-termal-\u00f6l\u00e7\u00fcm-50x37.jpg 50w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/03\/elektrik-motorlar\u0131nda-termal-\u00f6l\u00e7\u00fcm-100x75.jpg 100w\" sizes=\"auto, (max-width:767px) 480px, 640px\" \/><\/a><p id=\"caption-attachment-5113\" class=\"wp-caption-text\">Errors that reduce energy efficiency are detected by performing thermal measurements on electric motors.<\/p><\/div>\n<div id=\"attachment_5115\" style=\"width: 655px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/03\/pano-termal-\u00f6l\u00e7\u00fcm.jpg\" rel=\"attachment wp-att-5115\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-5115\" class=\" wp-image-5115\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/03\/pano-termal-\u00f6l\u00e7\u00fcm.jpg\" alt=\"Elektriksel ba\u011flant\u0131lar\u0131n\u0131z\u0131 termal \u00f6l\u00e7\u00fcm metodu ile kontrol edebilirsiniz\" width=\"645\" height=\"484\" srcset=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/03\/pano-termal-\u00f6l\u00e7\u00fcm.jpg 650w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/03\/pano-termal-\u00f6l\u00e7\u00fcm-300x225.jpg 300w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/03\/pano-termal-\u00f6l\u00e7\u00fcm-194x146.jpg 194w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/03\/pano-termal-\u00f6l\u00e7\u00fcm-50x38.jpg 50w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/03\/pano-termal-\u00f6l\u00e7\u00fcm-100x75.jpg 100w\" sizes=\"auto, (max-width:767px) 480px, 645px\" \/><\/a><p id=\"caption-attachment-5115\" class=\"wp-caption-text\">You can inspect your electrical connections using the thermal measurement method<\/p><\/div>\n<h3><strong><span style=\"color: #ff6600;\">Internal Installation Inspection Report<\/span><\/strong><\/h3>\n<p>According to regulations, electrical internal installation inspections must be performed once a year. You can download the electrical internal installation inspection (examination) report from the link below.<\/p>\n<p style=\"text-align: center;\"><strong><a href=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/03\/i\u00e7-tesisat-kontrol-raporu.pdf\" target=\"_blank\" rel=\"noopener\">Internal Installation Inspection Report<\/a><\/strong><\/p>\n<p><iframe loading=\"lazy\" title=\"Elektrik \u0130\u00e7  Tesisat Kontrol\u00fc\" width=\"1220\" height=\"686\" src=\"https:\/\/www.youtube.com\/embed\/qzLA37motsI?feature=oembed\" frameborder=\"0\" allow=\"accelerometer; autoplay; clipboard-write; encrypted-media; gyroscope; picture-in-picture; web-share\" referrerpolicy=\"strict-origin-when-cross-origin\" allowfullscreen><\/iframe><\/p>\n<blockquote>\n<p style=\"text-align: center;\">You can immediately request measurement and inspection by filling out the form below.<\/p>\n<\/blockquote>\n\n<div class=\"wpcf7 no-js\" id=\"wpcf7-f52162-o1\" lang=\"en-US\" dir=\"ltr\" data-wpcf7-id=\"52162\">\n<div class=\"screen-reader-response\"><p role=\"status\" aria-live=\"polite\" aria-atomic=\"true\"><\/p> <ul><\/ul><\/div>\n<form action=\"\/en\/wp-json\/wp\/v2\/posts\/53735#wpcf7-f52162-o1\" method=\"post\" class=\"wpcf7-form init\" aria-label=\"Contact form\" novalidate=\"novalidate\" data-status=\"init\">\n<fieldset class=\"hidden-fields-container\"><input type=\"hidden\" name=\"_wpcf7\" value=\"52162\" \/><input type=\"hidden\" name=\"_wpcf7_version\" value=\"6.1.5\" \/><input type=\"hidden\" name=\"_wpcf7_locale\" value=\"en_US\" \/><input type=\"hidden\" name=\"_wpcf7_unit_tag\" value=\"wpcf7-f52162-o1\" \/><input type=\"hidden\" name=\"_wpcf7_container_post\" value=\"0\" \/><input type=\"hidden\" name=\"_wpcf7_posted_data_hash\" value=\"\" \/><input type=\"hidden\" name=\"_wpcf7_recaptcha_response\" value=\"\" \/>\n<\/fieldset>\n<div class=\"column one-second\">\n\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-name\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-text wpcf7-validates-as-required\" aria-required=\"true\" aria-invalid=\"false\" placeholder=\"Full Name\" value=\"\" type=\"text\" name=\"your-name\" \/><\/span>\n\t<\/p>\n<\/div>\n<div class=\"column one-second\">\n\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-email\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-email wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-email\" aria-required=\"true\" aria-invalid=\"false\" placeholder=\"Email\" value=\"\" type=\"email\" name=\"your-email\" \/><\/span>\n\t<\/p>\n<\/div>\n<div class=\"column one\">\n\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"tel-196\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-tel wpcf7-validates-as-required wpcf7-text wpcf7-validates-as-tel\" aria-required=\"true\" aria-invalid=\"false\" placeholder=\"Phone\" value=\"\" type=\"tel\" name=\"tel-196\" \/><\/span>\n\t<\/p>\n<\/div>\n<div class=\"column one\">\n\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-subject\"><input size=\"40\" maxlength=\"400\" class=\"wpcf7-form-control wpcf7-text\" aria-invalid=\"false\" placeholder=\"Your Position in the Company\" value=\"\" type=\"text\" name=\"your-subject\" \/><\/span>\n\t<\/p>\n<\/div>\n<div class=\"column one\">\n\t<p><span class=\"wpcf7-form-control-wrap\" data-name=\"your-message\"><textarea cols=\"40\" rows=\"5\" maxlength=\"2000\" class=\"wpcf7-form-control wpcf7-textarea\" aria-invalid=\"false\" placeholder=\"Message\" name=\"your-message\"><\/textarea><\/span>\n\t<\/p>\n<\/div>\n<div class=\"column one\">\n\t<p><input class=\"wpcf7-form-control wpcf7-submit has-spinner button_full_width\" type=\"submit\" value=\"Send\" \/>\n\t<\/p>\n<\/div><div class=\"wpcf7-response-output\" aria-hidden=\"true\"><\/div>\n<\/form>\n<\/div>\n\n","protected":false},"excerpt":{"rendered":"<p>Industrial Maintenance refers to all interventions that minimize equipment failures in the field, extend their service life, and ensure the continuity of the enterprise\u2019s established operations.<span class=\"excerpt-hellip\"> [\u2026]<\/span><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_joinchat":[],"footnotes":""},"categories":[193],"tags":[],"class_list":["post-53735","post","type-post","status-publish","format-standard","hentry","category-general"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v19.2.1 (Yoast SEO v27.5) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Electrical Internal Installation Inspection<\/title>\n<meta name=\"description\" content=\"Electrical internal installations may deteriorate over time, develop connection issues, or lose their functionality. Therefore, electrical internal installation inspections should be carried out regularly\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/yilkomer.com\/en\/electrical-internal-installation-inspection\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Electrical Internal Installation Inspection\" \/>\n<meta property=\"og:description\" content=\"Industrial Maintenance refers to all interventions that minimize equipment failures in the field, extend their service life, and ensure the continuity of\" \/>\n<meta property=\"og:url\" content=\"https:\/\/yilkomer.com\/en\/electrical-internal-installation-inspection\/\" \/>\n<meta property=\"og:site_name\" content=\"Y\u0131lkomer\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/yilkomer\" \/>\n<meta property=\"article:published_time\" content=\"2016-03-15T12:04:17+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-12-19T21:28:21+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/03\/termal-\u00f6l\u00e7\u00fcm-kontrol\u00fc.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"700\" \/>\n\t<meta property=\"og:image:height\" content=\"675\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/electrical-internal-installation-inspection\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/electrical-internal-installation-inspection\\\/\"},\"author\":{\"name\":\"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#\\\/schema\\\/person\\\/1378732ec91a59af36092fedd9f6f871\"},\"headline\":\"Electrical Internal Installation Inspection\",\"datePublished\":\"2016-03-15T12:04:17+00:00\",\"dateModified\":\"2025-12-19T21:28:21+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/electrical-internal-installation-inspection\\\/\"},\"wordCount\":519,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#organization\"},\"articleSection\":[\"General\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/yilkomer.com\\\/en\\\/electrical-internal-installation-inspection\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/electrical-internal-installation-inspection\\\/\",\"url\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/electrical-internal-installation-inspection\\\/\",\"name\":\"Electrical Internal Installation Inspection\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#website\"},\"datePublished\":\"2016-03-15T12:04:17+00:00\",\"dateModified\":\"2025-12-19T21:28:21+00:00\",\"description\":\"Electrical internal installations may deteriorate over time, develop connection issues, or lose their functionality. Therefore, electrical internal installation inspections should be carried out regularly\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/electrical-internal-installation-inspection\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/yilkomer.com\\\/en\\\/electrical-internal-installation-inspection\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/electrical-internal-installation-inspection\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Ana Sayfa\",\"item\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Electrical Internal Installation Inspection\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/\",\"name\":\"Y\u0131lkomer\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#organization\"},\"alternateName\":\"Y\u0131lkomer\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#organization\",\"name\":\"Yilkomer\",\"url\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/yilkomer.com\\\/wp-content\\\/uploads\\\/2015\\\/01\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/yilkomer.com\\\/wp-content\\\/uploads\\\/2015\\\/01\\\/logo.png\",\"width\":1000,\"height\":189,\"caption\":\"Yilkomer\"},\"image\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#\\\/schema\\\/person\\\/1378732ec91a59af36092fedd9f6f871\",\"name\":\"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi\",\"description\":\"Y\u0131lkomer (Y\u0131ld\u0131r\u0131mdan Korunma Merkezi) \u00fclkemizde y\u0131ld\u0131r\u0131mdan ve a\u015f\u0131r\u0131 gerilimden korunmada teknik eksiklikleri ortadan kald\u0131rarak tamamen standartlar ve m\u00fchendislik hesaplar\u0131na dayanarak sistem kurmay\u0131 hedeflemektedir.\",\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/yilkomer\",\"https:\\\/\\\/www.linkedin.com\\\/profile\\\/view?id=393173773&trk=nav_responsive_tab_profile\",\"https:\\\/\\\/x.com\\\/https:\\\/\\\/twitter.com\\\/yilkomer\",\"admin\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Electrical Internal Installation Inspection","description":"Electrical internal installations may deteriorate over time, develop connection issues, or lose their functionality. Therefore, electrical internal installation inspections should be carried out regularly","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/yilkomer.com\/en\/electrical-internal-installation-inspection\/","og_locale":"en_US","og_type":"article","og_title":"Electrical Internal Installation Inspection","og_description":"Industrial Maintenance refers to all interventions that minimize equipment failures in the field, extend their service life, and ensure the continuity of","og_url":"https:\/\/yilkomer.com\/en\/electrical-internal-installation-inspection\/","og_site_name":"Y\u0131lkomer","article_author":"https:\/\/www.facebook.com\/yilkomer","article_published_time":"2016-03-15T12:04:17+00:00","article_modified_time":"2025-12-19T21:28:21+00:00","og_image":[{"width":700,"height":675,"url":"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/03\/termal-\u00f6l\u00e7\u00fcm-kontrol\u00fc.jpg","type":"image\/jpeg"}],"author":"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi","twitter_misc":{"Written by":"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/yilkomer.com\/en\/electrical-internal-installation-inspection\/#article","isPartOf":{"@id":"https:\/\/yilkomer.com\/en\/electrical-internal-installation-inspection\/"},"author":{"name":"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi","@id":"https:\/\/yilkomer.com\/en\/#\/schema\/person\/1378732ec91a59af36092fedd9f6f871"},"headline":"Electrical Internal Installation Inspection","datePublished":"2016-03-15T12:04:17+00:00","dateModified":"2025-12-19T21:28:21+00:00","mainEntityOfPage":{"@id":"https:\/\/yilkomer.com\/en\/electrical-internal-installation-inspection\/"},"wordCount":519,"commentCount":0,"publisher":{"@id":"https:\/\/yilkomer.com\/en\/#organization"},"articleSection":["General"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/yilkomer.com\/en\/electrical-internal-installation-inspection\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/yilkomer.com\/en\/electrical-internal-installation-inspection\/","url":"https:\/\/yilkomer.com\/en\/electrical-internal-installation-inspection\/","name":"Electrical Internal Installation Inspection","isPartOf":{"@id":"https:\/\/yilkomer.com\/en\/#website"},"datePublished":"2016-03-15T12:04:17+00:00","dateModified":"2025-12-19T21:28:21+00:00","description":"Electrical internal installations may deteriorate over time, develop connection issues, or lose their functionality. Therefore, electrical internal installation inspections should be carried out regularly","breadcrumb":{"@id":"https:\/\/yilkomer.com\/en\/electrical-internal-installation-inspection\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/yilkomer.com\/en\/electrical-internal-installation-inspection\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/yilkomer.com\/en\/electrical-internal-installation-inspection\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Ana Sayfa","item":"https:\/\/yilkomer.com\/en\/"},{"@type":"ListItem","position":2,"name":"Electrical Internal Installation Inspection"}]},{"@type":"WebSite","@id":"https:\/\/yilkomer.com\/en\/#website","url":"https:\/\/yilkomer.com\/en\/","name":"Y\u0131lkomer","description":"","publisher":{"@id":"https:\/\/yilkomer.com\/en\/#organization"},"alternateName":"Y\u0131lkomer","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/yilkomer.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/yilkomer.com\/en\/#organization","name":"Yilkomer","url":"https:\/\/yilkomer.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/yilkomer.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/01\/logo.png","contentUrl":"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/01\/logo.png","width":1000,"height":189,"caption":"Yilkomer"},"image":{"@id":"https:\/\/yilkomer.com\/en\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/yilkomer.com\/en\/#\/schema\/person\/1378732ec91a59af36092fedd9f6f871","name":"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi","description":"Y\u0131lkomer (Y\u0131ld\u0131r\u0131mdan Korunma Merkezi) \u00fclkemizde y\u0131ld\u0131r\u0131mdan ve a\u015f\u0131r\u0131 gerilimden korunmada teknik eksiklikleri ortadan kald\u0131rarak tamamen standartlar ve m\u00fchendislik hesaplar\u0131na dayanarak sistem kurmay\u0131 hedeflemektedir.","sameAs":["https:\/\/www.facebook.com\/yilkomer","https:\/\/www.linkedin.com\/profile\/view?id=393173773&trk=nav_responsive_tab_profile","https:\/\/x.com\/https:\/\/twitter.com\/yilkomer","admin"]}]}},"_links":{"self":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts\/53735","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/comments?post=53735"}],"version-history":[{"count":2,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts\/53735\/revisions"}],"predecessor-version":[{"id":53746,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts\/53735\/revisions\/53746"}],"wp:attachment":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/media?parent=53735"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/categories?post=53735"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/tags?post=53735"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}