{"id":52820,"date":"2022-07-17T11:36:49","date_gmt":"2022-07-17T08:36:49","guid":{"rendered":"https:\/\/yilkomer.com\/telekom-baz-istasyonlari-ag-parafudr-urun-secimleri\/"},"modified":"2026-08-26T10:51:49","modified_gmt":"2026-08-26T07:51:49","slug":"low-voltage-spd-product-selection-for-telecom-base-stations","status":"publish","type":"post","link":"https:\/\/yilkomer.com\/en\/low-voltage-spd-product-selection-for-telecom-base-stations\/","title":{"rendered":"Low-Voltage SPD Product Selection for Telecom Base Stations"},"content":{"rendered":"<div class=\"vgblk-rw-wrapper limit-wrapper\">Lightning protection system design for telecom base stations emerges as a result of experience, professionalism, and correct product integration. These stations, which receive thousands of strikes annually, are extremely difficult to access. In addition to thousands of impacts, base stations are also exposed to the most powerful lightning strikes, and due to the requirement for sustainable operation, they represent a complete case study. The operational cost of lightning-related damage to a base station over time can be equivalent to the cost of installing a new station. In short, these stations must be absolutely protected against lightning strikes. However, protecting base stations with conventional methods is quite difficult. Conventional surge arresters are insufficient at such heights under maximum Iimp values due to limited capacity. At this exact point, Raycap products\u2014protecting tens of thousands of facilities worldwide\u2014emerge as the solution. In this article, we will summarize which product should be used at which point.<\/p>\n<p><img fetchpriority=\"high\" decoding=\"async\" class=\"alignnone size-full wp-image-23992\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2022\/07\/Raycap-strikesorb-.jpg\" alt=\"\" width=\"1046\" height=\"683\" \/><\/p>\n<p>As you know, Raycap Strikesorb systems are the world\u2019s most advanced low-voltage surge protection systems. They can provide protection even against 200 kA impulses per phase. They are also capable of absorbing an unlimited number of surges and can operate without requiring a low grounding resistance value. These products, which can be connected inline (series) to the system, offer outstanding protection with a service life of 20 years.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-23993\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2022\/07\/Telekom-kulesini-.jpg\" alt=\"\" width=\"677\" height=\"261\" \/><\/p>\n<p>Before starting to protect the telecom tower, let us take a look at lightning protection zone areas within the scope of IEC 62305 Standards.<\/p>\n<p>LPZ 0A \u2013 Area that may be exposed to a direct lightning strike.<br \/>\nLPZ 0B \u2013 Protected against direct lightning strikes but electrically inducible.<br \/>\nLPZ 1 \u2013 Exposed to all electrical surges and must be protected with SPDs.<br \/>\nLPZ 2 \u2013 Must be protected against all surges with low-voltage SPD systems.<\/p>\n<p><img decoding=\"async\" class=\"alignnone size-full wp-image-23994\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2022\/07\/IEC-Standarti.jpg\" alt=\"\" width=\"906\" height=\"427\" \/><\/p>\n<p>When we examine the zone areas defined in the IEC Standard, we once again understand the importance of using low-voltage SPDs. Even if the strike is not direct, we must protect against the electrical effects of lightning in all zone areas. At this point, the base station must be protected according to the principle of coordinated (cascaded) protection.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-23995\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2022\/07\/Raycap-Rayvoss-sistemi.jpg\" alt=\"\" width=\"907\" height=\"421\" \/><\/p>\n<p>First of all, protection should be provided at the main incoming point of the facility with the Raycap Rayvoss system. In addition, the Raydin XV system should be integrated into the distribution panel.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-23996\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2022\/07\/Telekom-baz-istasyonu.jpg\" alt=\"\" width=\"905\" height=\"535\" \/><\/p>\n<p>One of the most frequently failing systems in telecom base stations is generators. Generator systems should primarily be protected with Raycap Raydin systems.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-23997\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2022\/07\/ana-giris-urunleri.jpg\" alt=\"\" width=\"907\" height=\"554\" \/><\/p>\n<p>After protecting the main incoming line and generator, the UPS, DC lines, coaxial and Ethernet lines, and secondary power panels in the facility should also be protected.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-23998\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2022\/07\/baz-istasyonu.jpg\" alt=\"\" width=\"907\" height=\"519\" \/><\/p>\n<p>On the base station mast, coaxial and power line protections must also be implemented.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-23999\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2022\/07\/Tesis-yildirimdan-korunmasi.jpg\" alt=\"\" width=\"907\" height=\"510\" \/><\/p>\n<p>After installing the correct surge protection systems so that no exposed point remains in the facility, an equipotential bonding check must be carried out throughout the site. Against the physical effects of direct lightning strikes, protection should also be provided using insulated passive air terminals and insulated down-conductor systems.<\/p>\n<p>Raycap Strikesorb technology is the most suitable lightning protection solution for facilities at altitudes of 1500 meters and above. For sites suffering from chronic lightning problems, Raycap Strikesorb low-voltage SPD systems provide a definitive solution. For detailed information and to request a site survey, you can contact the Yilkomer expert team.<\/p><\/div>\n<p><!-- .vgblk-rw-wrapper --><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Lightning protection system design for telecom base stations emerges as a result of experience, professionalism, and correct product integration. These stations, which receive thousands of strikes annually, are extremely difficult to access. In addition to thousands of impacts, base stations are also exposed to the most powerful lightning strikes, and due to the requirement for&#8230;<\/p>\n","protected":false},"author":1,"featured_media":994345,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[5],"tags":[],"class_list":["post-52820","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-general"],"_links":{"self":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts\/52820","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/comments?post=52820"}],"version-history":[{"count":1,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts\/52820\/revisions"}],"predecessor-version":[{"id":993799,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts\/52820\/revisions\/993799"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/media\/994345"}],"wp:attachment":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/media?parent=52820"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/categories?post=52820"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/tags?post=52820"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}