{"id":52102,"date":"2023-12-17T12:16:29","date_gmt":"2023-12-17T09:16:29","guid":{"rendered":"https:\/\/yilkomer.com\/baralara-dogrudan-montajlanan-alcak-gerilim-parafudrlari\/"},"modified":"2025-12-19T14:44:41","modified_gmt":"2025-12-19T11:44:41","slug":"busbar-mounted-low-voltage-surge-protective-devices","status":"publish","type":"post","link":"https:\/\/yilkomer.com\/en\/busbar-mounted-low-voltage-surge-protective-devices\/","title":{"rendered":"Busbar-Mounted Low Voltage Surge Protective Devices"},"content":{"rendered":"<h2 style=\"text-align: center;\">&nbsp;Raycap PROTEC ZPS T1H SERIES<\/h2>\n<p>The Raycap<strong> PROTEC ZPS T1H<\/strong> Series surge protection system is designed as a low voltage surge arrester (LVSA) system for busbars. These protective devices are specifically designed to be directly mounted on busbars in order to limit overvoltages in low voltage electrical systems. Busbars are conductors or bars that electrically connect different components of a power distribution system such as busbars, generators, transformers, and loads. Overvoltages, which are sudden voltage increases beyond the normal operating range, can result from various factors including lightning strikes, switching operations, or faults in the power system.<\/p>\n<h3>Functionality<\/h3>\n<p>LVSAs are designed to divert transient overvoltages to ground, preventing them from reaching and damaging sensitive equipment connected to the busbars. They operate by providing a low-impedance path to ground for excess current and effectively bypassing the connected equipment. At this point, the Raycap PROTEC ZPS T1H Series is nearly perfect in system protection in terms of both protection values and ease of application. In this mounting configuration, where cable distance is eliminated, the Up level is reduced to a very low value.<\/p>\n<p style=\"text-align: center;\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-33336\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2023\/12\/Raycap-ProTec-ZPS-T1H-300-31-R-L-order-yilkomercode-59.webp\" alt=\"\" width=\"996\" height=\"881\" srcset=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2023\/12\/Raycap-ProTec-ZPS-T1H-300-31-R-L-order-yilkomercode-59.webp 996w, https:\/\/yilkomer.com\/wp-content\/uploads\/2023\/12\/Raycap-ProTec-ZPS-T1H-300-31-R-L-order-yilkomercode-59-800x708.webp 800w, https:\/\/yilkomer.com\/wp-content\/uploads\/2023\/12\/Raycap-ProTec-ZPS-T1H-300-31-R-L-order-yilkomercode-59-300x265.webp 300w, https:\/\/yilkomer.com\/wp-content\/uploads\/2023\/12\/Raycap-ProTec-ZPS-T1H-300-31-R-L-order-yilkomercode-59-768x679.webp 768w, https:\/\/yilkomer.com\/wp-content\/uploads\/2023\/12\/Raycap-ProTec-ZPS-T1H-300-31-R-L-order-yilkomercode-59-85x75.webp 85w, https:\/\/yilkomer.com\/wp-content\/uploads\/2023\/12\/Raycap-ProTec-ZPS-T1H-300-31-R-L-order-yilkomercode-59-814x720.webp 814w, https:\/\/yilkomer.com\/wp-content\/uploads\/2023\/12\/Raycap-ProTec-ZPS-T1H-300-31-R-L-order-yilkomercode-59-480x425.webp 480w\" sizes=\"auto, (max-width:767px) 480px, (max-width:996px) 100vw, 996px\" \/><\/p>\n<h3>Voltage Rating<\/h3>\n<p>Low voltage surge arresters typically have voltage ratings up to 1000V or slightly higher, depending on the application and the specific requirements of the electrical system.<\/p>\n<h4>Installation:<\/h4>\n<p>LVSAs are mounted on busbars or near the equipment they are intended to protect.<\/p>\n<p>Proper installation is crucial to ensure that the surge arrester responds quickly to overvoltage events.<\/p>\n<h3>Protection Technology<\/h3>\n<p>LVSAs are the result of a hybrid design consisting of a series of metal oxide varistors (MOV) and GDT systems, and they also include other semiconductor-based devices. MOVs are the most commonly used components in surge arresters due to their ability to rapidly change resistance in response to voltage variations.<\/p>\n<h3>Response Time<\/h3>\n<p>LVSAs must have a fast response time in order to effectively limit overvoltages.<\/p>\n<p>The response time is typically in the nanosecond range.<\/p>\n<h4>Coordination with Other Protection Devices<\/h4>\n<p>LVSAs are usually part of a comprehensive surge protection strategy that may also include other devices such as lightning rods, surge suppressors, and protective relays.<\/p>\n<h4>Testing and Maintenance<\/h4>\n<p>Periodic testing and maintenance are essential to ensure the continued effectiveness of surge arresters.<\/p>\n<p>Testing may include measuring the resistance of the surge arrester or performing diagnostic tests to evaluate its performance.<\/p>\n<h4><strong>Standards and Compliance<\/strong><\/h4>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"size-full wp-image-33334 alignnone\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2023\/12\/Busbar-Products-Comp-yilkomer.webp\" alt=\"\" width=\"780\" height=\"520\" srcset=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2023\/12\/Busbar-Products-Comp-yilkomer.webp 780w, https:\/\/yilkomer.com\/wp-content\/uploads\/2023\/12\/Busbar-Products-Comp-yilkomer-300x200.webp 300w, https:\/\/yilkomer.com\/wp-content\/uploads\/2023\/12\/Busbar-Products-Comp-yilkomer-768x512.webp 768w, https:\/\/yilkomer.com\/wp-content\/uploads\/2023\/12\/Busbar-Products-Comp-yilkomer-113x75.webp 113w, https:\/\/yilkomer.com\/wp-content\/uploads\/2023\/12\/Busbar-Products-Comp-yilkomer-480x320.webp 480w\" sizes=\"auto, (max-width:767px) 480px, (max-width:780px) 100vw, 780px\" \/><\/p>\n<p>Surge arresters for busbars must comply with relevant international standards and regulations such as IEC 61643 to ensure their quality and performance.<\/p>\n<p>It is important to consult electrical engineers or power system protection specialists to determine the specific requirements and appropriate selection of low voltage surge arresters for busbars according to the characteristics of the electrical system they are intended to protect.<\/p>\n<p>You can quickly contact Y\u0131lkomer engineers via the Y\u0131lkomer contact section.<\/p>\n<p>You can download the product technical datasheet using the button below.<\/p>\n<p><a class=\"fasc-button fasc-size-large fasc-type-flat fasc-rounded-medium fasc-style-bold\" style=\"background-color: #ffa600; color: #ffffff;\" href=\"https:\/\/www.raycap.com\/wp-content\/uploads\/2020\/09\/ProTec-ZPS-31-R-F-L_G29-00-823.pdf\">DOWNLOAD<\/a><\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>&nbsp;Raycap PROTEC ZPS T1H SERIES The Raycap PROTEC ZPS T1H Series surge protection system is designed as a low voltage surge arrester (LVSA) system for busbars.<span class=\"excerpt-hellip\"> [\u2026]<\/span><\/p>\n","protected":false},"author":1,"featured_media":52104,"comment_status":"open","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_joinchat":[],"footnotes":""},"categories":[193],"tags":[],"class_list":["post-52102","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-general"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v19.2.1 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Busbar-Mounted Low Voltage Surge Protective Devices | Y\u0131lkomer<\/title>\n<meta name=\"description\" content=\"Y\u0131lkomer\u2019s Raycap PROTEC ZPS T1H Series surge arrester provides ideal protection for busbars. Low Voltage Surge Arresters Directly Mounted on Busbars\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/yilkomer.com\/en\/busbar-mounted-low-voltage-surge-protective-devices\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Busbar-Mounted Low Voltage Surge Protective Devices\" \/>\n<meta property=\"og:description\" content=\"&nbsp;Raycap PROTEC ZPS T1H SERIES The Raycap PROTEC ZPS T1H Series surge protection system is designed as a low voltage surge arrester (LVSA) system for\" \/>\n<meta property=\"og:url\" content=\"https:\/\/yilkomer.com\/en\/busbar-mounted-low-voltage-surge-protective-devices\/\" \/>\n<meta property=\"og:site_name\" content=\"Y\u0131lkomer\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/yilkomer\" \/>\n<meta property=\"article:published_time\" content=\"2023-12-17T09:16:29+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-12-19T11:44:41+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2023\/12\/ProTec-60-compostion-yilkomer.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1800\" \/>\n\t<meta property=\"og:image:height\" content=\"930\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/busbar-mounted-low-voltage-surge-protective-devices\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/busbar-mounted-low-voltage-surge-protective-devices\\\/\"},\"author\":{\"name\":\"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#\\\/schema\\\/person\\\/1378732ec91a59af36092fedd9f6f871\"},\"headline\":\"Busbar-Mounted Low Voltage Surge Protective Devices\",\"datePublished\":\"2023-12-17T09:16:29+00:00\",\"dateModified\":\"2025-12-19T11:44:41+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/busbar-mounted-low-voltage-surge-protective-devices\\\/\"},\"wordCount\":481,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/busbar-mounted-low-voltage-surge-protective-devices\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/yilkomer.com\\\/wp-content\\\/uploads\\\/2023\\\/12\\\/ProTec-60-compostion-yilkomer.webp\",\"articleSection\":[\"General\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/yilkomer.com\\\/en\\\/busbar-mounted-low-voltage-surge-protective-devices\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/busbar-mounted-low-voltage-surge-protective-devices\\\/\",\"url\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/busbar-mounted-low-voltage-surge-protective-devices\\\/\",\"name\":\"Busbar-Mounted Low Voltage Surge Protective Devices | Y\u0131lkomer\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/busbar-mounted-low-voltage-surge-protective-devices\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/busbar-mounted-low-voltage-surge-protective-devices\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/yilkomer.com\\\/wp-content\\\/uploads\\\/2023\\\/12\\\/ProTec-60-compostion-yilkomer.webp\",\"datePublished\":\"2023-12-17T09:16:29+00:00\",\"dateModified\":\"2025-12-19T11:44:41+00:00\",\"description\":\"Y\u0131lkomer\u2019s Raycap PROTEC ZPS T1H Series surge arrester provides ideal protection for busbars. Low Voltage Surge Arresters Directly Mounted on Busbars\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/busbar-mounted-low-voltage-surge-protective-devices\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/yilkomer.com\\\/en\\\/busbar-mounted-low-voltage-surge-protective-devices\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/busbar-mounted-low-voltage-surge-protective-devices\\\/#primaryimage\",\"url\":\"https:\\\/\\\/yilkomer.com\\\/wp-content\\\/uploads\\\/2023\\\/12\\\/ProTec-60-compostion-yilkomer.webp\",\"contentUrl\":\"https:\\\/\\\/yilkomer.com\\\/wp-content\\\/uploads\\\/2023\\\/12\\\/ProTec-60-compostion-yilkomer.webp\",\"width\":1800,\"height\":930,\"caption\":\"Y\u0131lkomer ProTec\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/busbar-mounted-low-voltage-surge-protective-devices\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Ana Sayfa\",\"item\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Busbar-Mounted Low Voltage Surge Protective Devices\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/\",\"name\":\"Y\u0131lkomer\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#organization\"},\"alternateName\":\"Y\u0131lkomer\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#organization\",\"name\":\"Yilkomer\",\"url\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/yilkomer.com\\\/wp-content\\\/uploads\\\/2015\\\/01\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/yilkomer.com\\\/wp-content\\\/uploads\\\/2015\\\/01\\\/logo.png\",\"width\":1000,\"height\":189,\"caption\":\"Yilkomer\"},\"image\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#\\\/schema\\\/person\\\/1378732ec91a59af36092fedd9f6f871\",\"name\":\"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi\",\"description\":\"Y\u0131lkomer (Y\u0131ld\u0131r\u0131mdan Korunma Merkezi) \u00fclkemizde y\u0131ld\u0131r\u0131mdan ve a\u015f\u0131r\u0131 gerilimden korunmada teknik eksiklikleri ortadan kald\u0131rarak tamamen standartlar ve m\u00fchendislik hesaplar\u0131na dayanarak sistem kurmay\u0131 hedeflemektedir.\",\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/yilkomer\",\"https:\\\/\\\/www.linkedin.com\\\/profile\\\/view?id=393173773&trk=nav_responsive_tab_profile\",\"https:\\\/\\\/x.com\\\/https:\\\/\\\/twitter.com\\\/yilkomer\",\"admin\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Busbar-Mounted Low Voltage Surge Protective Devices | Y\u0131lkomer","description":"Y\u0131lkomer\u2019s Raycap PROTEC ZPS T1H Series surge arrester provides ideal protection for busbars. Low Voltage Surge Arresters Directly Mounted on Busbars","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/yilkomer.com\/en\/busbar-mounted-low-voltage-surge-protective-devices\/","og_locale":"en_US","og_type":"article","og_title":"Busbar-Mounted Low Voltage Surge Protective Devices","og_description":"&nbsp;Raycap PROTEC ZPS T1H SERIES The Raycap PROTEC ZPS T1H Series surge protection system is designed as a low voltage surge arrester (LVSA) system for","og_url":"https:\/\/yilkomer.com\/en\/busbar-mounted-low-voltage-surge-protective-devices\/","og_site_name":"Y\u0131lkomer","article_author":"https:\/\/www.facebook.com\/yilkomer","article_published_time":"2023-12-17T09:16:29+00:00","article_modified_time":"2025-12-19T11:44:41+00:00","og_image":[{"width":1800,"height":930,"url":"https:\/\/yilkomer.com\/wp-content\/uploads\/2023\/12\/ProTec-60-compostion-yilkomer.webp","type":"image\/webp"}],"author":"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi","twitter_misc":{"Written by":"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/yilkomer.com\/en\/busbar-mounted-low-voltage-surge-protective-devices\/#article","isPartOf":{"@id":"https:\/\/yilkomer.com\/en\/busbar-mounted-low-voltage-surge-protective-devices\/"},"author":{"name":"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi","@id":"https:\/\/yilkomer.com\/en\/#\/schema\/person\/1378732ec91a59af36092fedd9f6f871"},"headline":"Busbar-Mounted Low Voltage Surge Protective Devices","datePublished":"2023-12-17T09:16:29+00:00","dateModified":"2025-12-19T11:44:41+00:00","mainEntityOfPage":{"@id":"https:\/\/yilkomer.com\/en\/busbar-mounted-low-voltage-surge-protective-devices\/"},"wordCount":481,"commentCount":0,"publisher":{"@id":"https:\/\/yilkomer.com\/en\/#organization"},"image":{"@id":"https:\/\/yilkomer.com\/en\/busbar-mounted-low-voltage-surge-protective-devices\/#primaryimage"},"thumbnailUrl":"https:\/\/yilkomer.com\/wp-content\/uploads\/2023\/12\/ProTec-60-compostion-yilkomer.webp","articleSection":["General"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/yilkomer.com\/en\/busbar-mounted-low-voltage-surge-protective-devices\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/yilkomer.com\/en\/busbar-mounted-low-voltage-surge-protective-devices\/","url":"https:\/\/yilkomer.com\/en\/busbar-mounted-low-voltage-surge-protective-devices\/","name":"Busbar-Mounted Low Voltage Surge Protective Devices | Y\u0131lkomer","isPartOf":{"@id":"https:\/\/yilkomer.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/yilkomer.com\/en\/busbar-mounted-low-voltage-surge-protective-devices\/#primaryimage"},"image":{"@id":"https:\/\/yilkomer.com\/en\/busbar-mounted-low-voltage-surge-protective-devices\/#primaryimage"},"thumbnailUrl":"https:\/\/yilkomer.com\/wp-content\/uploads\/2023\/12\/ProTec-60-compostion-yilkomer.webp","datePublished":"2023-12-17T09:16:29+00:00","dateModified":"2025-12-19T11:44:41+00:00","description":"Y\u0131lkomer\u2019s Raycap PROTEC ZPS T1H Series surge arrester provides ideal protection for busbars. Low Voltage Surge Arresters Directly Mounted on Busbars","breadcrumb":{"@id":"https:\/\/yilkomer.com\/en\/busbar-mounted-low-voltage-surge-protective-devices\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/yilkomer.com\/en\/busbar-mounted-low-voltage-surge-protective-devices\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/yilkomer.com\/en\/busbar-mounted-low-voltage-surge-protective-devices\/#primaryimage","url":"https:\/\/yilkomer.com\/wp-content\/uploads\/2023\/12\/ProTec-60-compostion-yilkomer.webp","contentUrl":"https:\/\/yilkomer.com\/wp-content\/uploads\/2023\/12\/ProTec-60-compostion-yilkomer.webp","width":1800,"height":930,"caption":"Y\u0131lkomer ProTec"},{"@type":"BreadcrumbList","@id":"https:\/\/yilkomer.com\/en\/busbar-mounted-low-voltage-surge-protective-devices\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Ana Sayfa","item":"https:\/\/yilkomer.com\/en\/"},{"@type":"ListItem","position":2,"name":"Busbar-Mounted Low Voltage Surge Protective Devices"}]},{"@type":"WebSite","@id":"https:\/\/yilkomer.com\/en\/#website","url":"https:\/\/yilkomer.com\/en\/","name":"Y\u0131lkomer","description":"","publisher":{"@id":"https:\/\/yilkomer.com\/en\/#organization"},"alternateName":"Y\u0131lkomer","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/yilkomer.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/yilkomer.com\/en\/#organization","name":"Yilkomer","url":"https:\/\/yilkomer.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/yilkomer.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/01\/logo.png","contentUrl":"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/01\/logo.png","width":1000,"height":189,"caption":"Yilkomer"},"image":{"@id":"https:\/\/yilkomer.com\/en\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/yilkomer.com\/en\/#\/schema\/person\/1378732ec91a59af36092fedd9f6f871","name":"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi","description":"Y\u0131lkomer (Y\u0131ld\u0131r\u0131mdan Korunma Merkezi) \u00fclkemizde y\u0131ld\u0131r\u0131mdan ve a\u015f\u0131r\u0131 gerilimden korunmada teknik eksiklikleri ortadan kald\u0131rarak tamamen standartlar ve m\u00fchendislik hesaplar\u0131na dayanarak sistem kurmay\u0131 hedeflemektedir.","sameAs":["https:\/\/www.facebook.com\/yilkomer","https:\/\/www.linkedin.com\/profile\/view?id=393173773&trk=nav_responsive_tab_profile","https:\/\/x.com\/https:\/\/twitter.com\/yilkomer","admin"]}]}},"_links":{"self":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts\/52102","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/comments?post=52102"}],"version-history":[{"count":2,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts\/52102\/revisions"}],"predecessor-version":[{"id":52117,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts\/52102\/revisions\/52117"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/media\/52104"}],"wp:attachment":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/media?parent=52102"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/categories?post=52102"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/tags?post=52102"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}