{"id":51782,"date":"2015-11-14T12:02:47","date_gmt":"2015-11-14T10:02:47","guid":{"rendered":"https:\/\/yilkomer.com\/parafudr-hakkinda-dogru-bilinen-yanlislar\/"},"modified":"2025-12-19T09:15:22","modified_gmt":"2025-12-19T06:15:22","slug":"common-misconceptions-about-surge-arresters","status":"publish","type":"post","link":"https:\/\/yilkomer.com\/en\/common-misconceptions-about-surge-arresters\/","title":{"rendered":"Common Misconceptions About Surge Arresters"},"content":{"rendered":"<p>Lightning and overvoltage protection is a process that requires expertise and must be carried out by experienced engineers in the field. Internal lightning protection systems, i.e., surge protectors (parafudr), are one of the most often neglected yet critical components of overvoltage protection. In this article, we have collected the common myths about <strong><span style=\"color: #ff6600;\"><a style=\"color: #ff6600;\" href=\"https:\/\/yilkomer.com\/de\/\" target=\"_blank\" rel=\"noopener noreferrer\">surge protectors<\/a><\/span><\/strong>.<\/p>\n<h2><strong><span style=\"color: #ff6600;\">1- Having an external lightning protection system like a lightning rod fully protects my facility from lightning effects.<\/span><\/strong><\/h2>\n<p>External lightning protection systems only protect facilities against the physical impact of lightning. Having an external lightning system does not mean your electrical devices are protected. Internal lightning protection (surge protectors) must be installed for electrical protection. Full protection requires integration of external lightning protection, internal lightning protection, equipotential bonding, and grounding.<\/p>\n<div id=\"attachment_4630\" style=\"width: 660px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/11\/parafudr-y\u0131ld\u0131r\u0131mdan-korunma.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-4630\" class=\"wp-image-4630 size-full\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/11\/parafudr-y\u0131ld\u0131r\u0131mdan-korunma.jpg\" alt=\"Using surge protectors is mandatory for facilities.\" width=\"650\" height=\"430\" srcset=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/11\/parafudr-y\u0131ld\u0131r\u0131mdan-korunma.jpg 650w, https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/11\/parafudr-y\u0131ld\u0131r\u0131mdan-korunma-300x198.jpg 300w, https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/11\/parafudr-y\u0131ld\u0131r\u0131mdan-korunma-221x146.jpg 221w, https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/11\/parafudr-y\u0131ld\u0131r\u0131mdan-korunma-50x33.jpg 50w, https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/11\/parafudr-y\u0131ld\u0131r\u0131mdan-korunma-113x75.jpg 113w\" sizes=\"auto, (max-width:767px) 480px, 650px\" \/><\/a><p id=\"caption-attachment-4630\" class=\"wp-caption-text\">Surge protector systems are essential for full protection against lightning and overvoltage.<\/p><\/div>\n<h2><span style=\"color: #ff6600;\"><strong>2- Lightning that does not strike directly cannot harm the facility. My facility is at a low level, so I don&#8217;t need surge protectors.<\/strong><\/span><\/h2>\n<p>Lightning can affect an area as a traveling impulse within a 2 km radius from the strike point. A commonly encountered scenario is that lightning strikes nearby systems and damages facilities via panels.<\/p>\n<div id=\"attachment_4631\" style=\"width: 600px\" class=\"wp-caption aligncenter\"><a href=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/11\/yildirim-zarar-gorseli.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-4631\" class=\"wp-image-4631 size-full\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/11\/yildirim-zarar-gorseli.jpg\" alt=\"Lightning-damage-illustration\" width=\"590\" height=\"440\" srcset=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/11\/yildirim-zarar-gorseli.jpg 590w, https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/11\/yildirim-zarar-gorseli-300x224.jpg 300w, https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/11\/yildirim-zarar-gorseli-196x146.jpg 196w, https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/11\/yildirim-zarar-gorseli-50x37.jpg 50w, https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/11\/yildirim-zarar-gorseli-101x75.jpg 101w\" sizes=\"auto, (max-width:767px) 480px, 590px\" \/><\/a><p id=\"caption-attachment-4631\" class=\"wp-caption-text\">Lightning does not need to strike directly to damage your facility; it can also affect it as a traveling impulse.<\/p><\/div>\n<h2><span style=\"color: #ff6600;\">3- I use surge protectors on my main panel. Therefore, I don&#8217;t need surge protectors on secondary panels.<\/span><\/h2>\n<p>Using surge protectors on the main panel does not mean secondary panels are protected. Most overvoltage impulses are facility-originated internal overvoltages and require protection with Class C surge protectors.<\/p>\n<blockquote>\n<p style=\"text-align: center;\">You may also be interested: <a href=\"https:\/\/yilkomer.com\/en\/surge-arrester-grounding\/\" target=\"_blank\" rel=\"noopener noreferrer\">Surge Protector Grounding<\/a><\/p>\n<\/blockquote>\n<h2><strong><span style=\"color: #ff6600;\">4- Main panels must use Class B surge protectors.<\/span><\/strong><\/h2>\n<p>Internal overvoltages pose higher risks than lightning impulses. Therefore, main panels may be damaged by these internal overvoltages. For better protection, use B+C class products that protect against both lightning impulses (10\/350 ms) and internal overvoltages (8\/20 ms).<\/p>\n<h2><span style=\"color: #ff6600;\"><strong>5- Standards do not make surge protector usage optional.<\/strong><\/span><\/h2>\n<p>According to IEC 62305 Lightning Protection Standard, internal lightning protection, i.e., surge protectors, is mandatory in facilities.<\/p>\n<h2><img loading=\"lazy\" decoding=\"async\" class=\"aligncenter wp-image-12084 size-medium\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/11\/T1HS_31_catalogd-300x232.jpg\" alt=\"Protection of electrical installations from lightning\" width=\"300\" height=\"232\" srcset=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/11\/T1HS_31_catalogd-300x232.jpg 300w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/11\/T1HS_31_catalogd-1024x794.jpg 1024w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/11\/T1HS_31_catalogd-768x595.jpg 768w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/11\/T1HS_31_catalogd-1536x1190.jpg 1536w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/11\/T1HS_31_catalogd-188x146.jpg 188w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/11\/T1HS_31_catalogd-50x39.jpg 50w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/11\/T1HS_31_catalogd-97x75.jpg 97w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/11\/T1HS_31_catalogd-929x720.jpg 929w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/11\/T1HS_31_catalogd-600x465.jpg 600w, https:\/\/yilkomer.com\/wp-content\/uploads\/2016\/11\/T1HS_31_catalogd.jpg 2048w\" sizes=\"auto, (max-width:767px) 300px, 300px\" \/><\/h2>\n<h2><span style=\"color: #ff6600;\">6- It does not matter where the surge protector is connected to the ground line.<\/span><\/h2>\n<p>Surge protectors should be connected to the ground line via the shortest distance. Cable cross-section is very important according to product class. Class B products: 16 mm\u00b2, Class C products: 6 mm\u00b2.<\/p>\n<h2><span style=\"color: #ff6600;\">7- The same surge protector can be used for all regions and facilities.<\/span><\/h2>\n<p>When selecting surge protectors for your facility, internal risk parameters must also be considered along with lightning risk calculations. Therefore, each facility should be analyzed by expert engineers before using surge protectors.<\/p>\n<h2><span style=\"color: #ff6600;\">8- I protect my main and secondary panels. My camera, data, power lines, and automation systems do not require separate protection.<\/span><\/h2>\n<p>CCTV, cameras, PLC, SCADA, and power lines are very sensitive systems. They must be protected with Class D sensitive surge protectors. In summary, stepwise protection should be implemented in the facility.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Lightning and overvoltage protection is a process that requires expertise and must be carried out by experienced engineers in the field. Internal lightning protection systems, i.e.,<span class=\"excerpt-hellip\"> [\u2026]<\/span><\/p>\n","protected":false},"author":1,"featured_media":51784,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_joinchat":[],"footnotes":""},"categories":[193],"tags":[],"class_list":["post-51782","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-general"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v19.2.1 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Common Misconceptions About Surge Arresters<\/title>\n<meta name=\"description\" content=\"Internal lightning protection systems, namely surge arresters, are one of the most important pillars of protection against lightning and overvoltage that are frequently neglected. In this article, surge arresters\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/yilkomer.com\/en\/common-misconceptions-about-surge-arresters\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Common Misconceptions About Surge Arresters\" \/>\n<meta property=\"og:description\" content=\"Lightning and overvoltage protection is a process that requires expertise and must be carried out by experienced engineers in the field. Internal\" \/>\n<meta property=\"og:url\" content=\"https:\/\/yilkomer.com\/en\/common-misconceptions-about-surge-arresters\/\" \/>\n<meta property=\"og:site_name\" content=\"Y\u0131lkomer\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/yilkomer\" \/>\n<meta property=\"article:published_time\" content=\"2015-11-14T10:02:47+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-12-19T06:15:22+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/11\/yildirim-zarar-gorseli.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"590\" \/>\n\t<meta property=\"og:image:height\" content=\"440\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/common-misconceptions-about-surge-arresters\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/common-misconceptions-about-surge-arresters\\\/\"},\"author\":{\"name\":\"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#\\\/schema\\\/person\\\/1378732ec91a59af36092fedd9f6f871\"},\"headline\":\"Common Misconceptions About Surge Arresters\",\"datePublished\":\"2015-11-14T10:02:47+00:00\",\"dateModified\":\"2025-12-19T06:15:22+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/common-misconceptions-about-surge-arresters\\\/\"},\"wordCount\":503,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/common-misconceptions-about-surge-arresters\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/yilkomer.com\\\/wp-content\\\/uploads\\\/2015\\\/11\\\/yildirim-zarar-gorseli.jpg\",\"articleSection\":[\"General\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/yilkomer.com\\\/en\\\/common-misconceptions-about-surge-arresters\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/common-misconceptions-about-surge-arresters\\\/\",\"url\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/common-misconceptions-about-surge-arresters\\\/\",\"name\":\"Common Misconceptions About Surge Arresters\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/common-misconceptions-about-surge-arresters\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/common-misconceptions-about-surge-arresters\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/yilkomer.com\\\/wp-content\\\/uploads\\\/2015\\\/11\\\/yildirim-zarar-gorseli.jpg\",\"datePublished\":\"2015-11-14T10:02:47+00:00\",\"dateModified\":\"2025-12-19T06:15:22+00:00\",\"description\":\"Internal lightning protection systems, namely surge arresters, are one of the most important pillars of protection against lightning and overvoltage that are frequently neglected. In this article, surge arresters\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/common-misconceptions-about-surge-arresters\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/yilkomer.com\\\/en\\\/common-misconceptions-about-surge-arresters\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/common-misconceptions-about-surge-arresters\\\/#primaryimage\",\"url\":\"https:\\\/\\\/yilkomer.com\\\/wp-content\\\/uploads\\\/2015\\\/11\\\/yildirim-zarar-gorseli.jpg\",\"contentUrl\":\"https:\\\/\\\/yilkomer.com\\\/wp-content\\\/uploads\\\/2015\\\/11\\\/yildirim-zarar-gorseli.jpg\",\"width\":590,\"height\":440},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/common-misconceptions-about-surge-arresters\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Ana Sayfa\",\"item\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Common Misconceptions About Surge Arresters\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/\",\"name\":\"Y\u0131lkomer\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#organization\"},\"alternateName\":\"Y\u0131lkomer\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#organization\",\"name\":\"Yilkomer\",\"url\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/yilkomer.com\\\/wp-content\\\/uploads\\\/2015\\\/01\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/yilkomer.com\\\/wp-content\\\/uploads\\\/2015\\\/01\\\/logo.png\",\"width\":1000,\"height\":189,\"caption\":\"Yilkomer\"},\"image\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#\\\/schema\\\/person\\\/1378732ec91a59af36092fedd9f6f871\",\"name\":\"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi\",\"description\":\"Y\u0131lkomer (Y\u0131ld\u0131r\u0131mdan Korunma Merkezi) \u00fclkemizde y\u0131ld\u0131r\u0131mdan ve a\u015f\u0131r\u0131 gerilimden korunmada teknik eksiklikleri ortadan kald\u0131rarak tamamen standartlar ve m\u00fchendislik hesaplar\u0131na dayanarak sistem kurmay\u0131 hedeflemektedir.\",\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/yilkomer\",\"https:\\\/\\\/www.linkedin.com\\\/profile\\\/view?id=393173773&trk=nav_responsive_tab_profile\",\"https:\\\/\\\/x.com\\\/https:\\\/\\\/twitter.com\\\/yilkomer\",\"admin\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Common Misconceptions About Surge Arresters","description":"Internal lightning protection systems, namely surge arresters, are one of the most important pillars of protection against lightning and overvoltage that are frequently neglected. In this article, surge arresters","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/yilkomer.com\/en\/common-misconceptions-about-surge-arresters\/","og_locale":"en_US","og_type":"article","og_title":"Common Misconceptions About Surge Arresters","og_description":"Lightning and overvoltage protection is a process that requires expertise and must be carried out by experienced engineers in the field. Internal","og_url":"https:\/\/yilkomer.com\/en\/common-misconceptions-about-surge-arresters\/","og_site_name":"Y\u0131lkomer","article_author":"https:\/\/www.facebook.com\/yilkomer","article_published_time":"2015-11-14T10:02:47+00:00","article_modified_time":"2025-12-19T06:15:22+00:00","og_image":[{"width":590,"height":440,"url":"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/11\/yildirim-zarar-gorseli.jpg","type":"image\/jpeg"}],"author":"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi","twitter_misc":{"Written by":"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/yilkomer.com\/en\/common-misconceptions-about-surge-arresters\/#article","isPartOf":{"@id":"https:\/\/yilkomer.com\/en\/common-misconceptions-about-surge-arresters\/"},"author":{"name":"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi","@id":"https:\/\/yilkomer.com\/en\/#\/schema\/person\/1378732ec91a59af36092fedd9f6f871"},"headline":"Common Misconceptions About Surge Arresters","datePublished":"2015-11-14T10:02:47+00:00","dateModified":"2025-12-19T06:15:22+00:00","mainEntityOfPage":{"@id":"https:\/\/yilkomer.com\/en\/common-misconceptions-about-surge-arresters\/"},"wordCount":503,"commentCount":0,"publisher":{"@id":"https:\/\/yilkomer.com\/en\/#organization"},"image":{"@id":"https:\/\/yilkomer.com\/en\/common-misconceptions-about-surge-arresters\/#primaryimage"},"thumbnailUrl":"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/11\/yildirim-zarar-gorseli.jpg","articleSection":["General"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/yilkomer.com\/en\/common-misconceptions-about-surge-arresters\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/yilkomer.com\/en\/common-misconceptions-about-surge-arresters\/","url":"https:\/\/yilkomer.com\/en\/common-misconceptions-about-surge-arresters\/","name":"Common Misconceptions About Surge Arresters","isPartOf":{"@id":"https:\/\/yilkomer.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/yilkomer.com\/en\/common-misconceptions-about-surge-arresters\/#primaryimage"},"image":{"@id":"https:\/\/yilkomer.com\/en\/common-misconceptions-about-surge-arresters\/#primaryimage"},"thumbnailUrl":"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/11\/yildirim-zarar-gorseli.jpg","datePublished":"2015-11-14T10:02:47+00:00","dateModified":"2025-12-19T06:15:22+00:00","description":"Internal lightning protection systems, namely surge arresters, are one of the most important pillars of protection against lightning and overvoltage that are frequently neglected. In this article, surge arresters","breadcrumb":{"@id":"https:\/\/yilkomer.com\/en\/common-misconceptions-about-surge-arresters\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/yilkomer.com\/en\/common-misconceptions-about-surge-arresters\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/yilkomer.com\/en\/common-misconceptions-about-surge-arresters\/#primaryimage","url":"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/11\/yildirim-zarar-gorseli.jpg","contentUrl":"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/11\/yildirim-zarar-gorseli.jpg","width":590,"height":440},{"@type":"BreadcrumbList","@id":"https:\/\/yilkomer.com\/en\/common-misconceptions-about-surge-arresters\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Ana Sayfa","item":"https:\/\/yilkomer.com\/en\/"},{"@type":"ListItem","position":2,"name":"Common Misconceptions About Surge Arresters"}]},{"@type":"WebSite","@id":"https:\/\/yilkomer.com\/en\/#website","url":"https:\/\/yilkomer.com\/en\/","name":"Y\u0131lkomer","description":"","publisher":{"@id":"https:\/\/yilkomer.com\/en\/#organization"},"alternateName":"Y\u0131lkomer","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/yilkomer.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/yilkomer.com\/en\/#organization","name":"Yilkomer","url":"https:\/\/yilkomer.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/yilkomer.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/01\/logo.png","contentUrl":"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/01\/logo.png","width":1000,"height":189,"caption":"Yilkomer"},"image":{"@id":"https:\/\/yilkomer.com\/en\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/yilkomer.com\/en\/#\/schema\/person\/1378732ec91a59af36092fedd9f6f871","name":"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi","description":"Y\u0131lkomer (Y\u0131ld\u0131r\u0131mdan Korunma Merkezi) \u00fclkemizde y\u0131ld\u0131r\u0131mdan ve a\u015f\u0131r\u0131 gerilimden korunmada teknik eksiklikleri ortadan kald\u0131rarak tamamen standartlar ve m\u00fchendislik hesaplar\u0131na dayanarak sistem kurmay\u0131 hedeflemektedir.","sameAs":["https:\/\/www.facebook.com\/yilkomer","https:\/\/www.linkedin.com\/profile\/view?id=393173773&trk=nav_responsive_tab_profile","https:\/\/x.com\/https:\/\/twitter.com\/yilkomer","admin"]}]}},"_links":{"self":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts\/51782","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/comments?post=51782"}],"version-history":[{"count":2,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts\/51782\/revisions"}],"predecessor-version":[{"id":51799,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts\/51782\/revisions\/51799"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/media\/51784"}],"wp:attachment":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/media?parent=51782"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/categories?post=51782"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/tags?post=51782"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}