{"id":51211,"date":"2015-09-17T13:37:16","date_gmt":"2015-09-17T10:37:16","guid":{"rendered":"https:\/\/yilkomer.com\/topraklama-tipleri-ve-dagitim-sebekeleri\/"},"modified":"2025-12-18T23:12:59","modified_gmt":"2025-12-18T20:12:59","slug":"grounding-types-and-distribution-networks","status":"publish","type":"post","link":"https:\/\/yilkomer.com\/en\/grounding-types-and-distribution-networks\/","title":{"rendered":"Grounding Types and Distribution Networks"},"content":{"rendered":"<p>International regulations define low-voltage distribution networks in three ways. According to the TS 3994 standard, these distribution networks are named as follows. The application of grounding types varies depending on the facility type and its importance. While our traditional network structure is TT, using IT systems and isolated transformers in hospitals is extremely important. The <span style=\"color: #ff6600;\"><em><strong><a href=\"https:\/\/yilkomer.com\/ag-parafudr\/\">LV Surge Arrester<\/a><\/strong><\/em><\/span> system selection also depends heavily on the grounding structure. Products should be selected and installed according to TT, TN, TNC, and TNS system characteristics. Choosing the wrong product for the wrong grounding type may cause protection issues. Therefore, site inspection is very important.<\/p>\n<blockquote><p>You can contact the Lightning Protection Center expert team for site inspection and LV surge arrester product selection.<\/p><\/blockquote>\n<ol>\n<li>TN System<\/li>\n<li>TT System<\/li>\n<li>IT System<\/li>\n<\/ol>\n<p>In these systems, named according to connection types, the first letter indicates the transformer grounding status, and the second letter indicates the device grounding status. T stands for grounded, N for neutral, I for isolated.<\/p>\n<blockquote>\n<p style=\"text-align: center;\">You may be interested: <strong><a href=\"https:\/\/yilkomer.com\/en\/topraklama-olcumu\/\" target=\"_blank\" rel=\"noopener\">Grounding Measurement<\/a><\/strong><\/p>\n<\/blockquote>\n<h2><span style=\"color: #ff6600;\">1-TT Networks<\/span><\/h2>\n<p>In TT networks, the star point of the network is grounded, providing operational grounding. The metal parts of the devices connected to the network are grounded separately from the operational grounding.<\/p>\n<div id=\"attachment_4369\" style=\"width: 398px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/tt-\u015febeke.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-4369\" class=\"size-full wp-image-4369\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/tt-\u015febeke.png\" alt=\"TT network\" width=\"388\" height=\"192\" srcset=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/tt-\u015febeke.png 388w, https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/tt-\u015febeke-300x148.png 300w, https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/tt-\u015febeke-260x129.png 260w, https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/tt-\u015febeke-50x25.png 50w, https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/tt-\u015febeke-150x75.png 150w\" sizes=\"auto, (max-width:767px) 388px, 388px\" \/><\/a><p id=\"caption-attachment-4369\" class=\"wp-caption-text\">TT network<\/p><\/div>\n<h2><span style=\"color: #ff6600;\"><strong>2-TN Networks<\/strong><\/span><\/h2>\n<p>The TN network system is widely used. In TN networks, the neutral point is directly grounded, providing operational grounding.<\/p>\n<p><strong>TN-C system:<\/strong> The protective conductor (PE) and neutral (N) are combined into a PEN conductor, which runs throughout the network.<\/p>\n<div id=\"attachment_4368\" style=\"width: 389px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/tn-c-\u015febeke.png\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-4368\" class=\"wp-image-4368 size-full\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/tn-c-\u015febeke.png\" alt=\"TN-C network\" width=\"379\" height=\"344\" srcset=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/tn-c-\u015febeke.png 379w, https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/tn-c-\u015febeke-300x272.png 300w, https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/tn-c-\u015febeke-161x146.png 161w, https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/tn-c-\u015febeke-50x45.png 50w, https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/tn-c-\u015febeke-83x75.png 83w\" sizes=\"auto, (max-width:767px) 379px, 379px\" \/><\/a><p id=\"caption-attachment-4368\" class=\"wp-caption-text\">TN-C System<\/p><\/div>\n<p><strong>TN-S system:<\/strong> In TN-S systems, the protective conductor and neutral are separate throughout the network.<\/p>\n<p><a href=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/tn-s-\u015febeke.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-4370\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/tn-s-\u015febeke.png\" alt=\"TN-S network\" width=\"379\" height=\"344\" srcset=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/tn-s-\u015febeke.png 379w, https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/tn-s-\u015febeke-300x272.png 300w, https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/tn-s-\u015febeke-161x146.png 161w, https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/tn-s-\u015febeke-50x45.png 50w, https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/tn-s-\u015febeke-83x75.png 83w\" sizes=\"auto, (max-width:767px) 379px, 379px\" \/><\/a><\/p>\n<p><strong>TN C-S System:<\/strong> In this system, PE and N conductors are separate in one part of the network and combined in another.<\/p>\n<p><a href=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/tn-c-s-\u015febeke.png\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-4371\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/tn-c-s-\u015febeke.png\" alt=\"TN-C-S network\" width=\"411\" height=\"346\" srcset=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/tn-c-s-\u015febeke.png 411w, https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/tn-c-s-\u015febeke-300x253.png 300w, https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/tn-c-s-\u015febeke-173x146.png 173w, https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/tn-c-s-\u015febeke-50x42.png 50w, https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/tn-c-s-\u015febeke-89x75.png 89w\" sizes=\"auto, (max-width:767px) 411px, 411px\" \/><\/a><\/p>\n<h2><span style=\"color: #ff6600;\"><strong>3-IT Networks<\/strong><\/span><\/h2>\n<p>In IT networks, the star point of the transformer is completely isolated from the ground or grounded through a high-impedance element (coil, resistor). Devices connected to this network are also grounded.<\/p>\n<p><a href=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/\u0131t-\u015febeke.jpg\"><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-full wp-image-4373\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/\u0131t-\u015febeke.jpg\" alt=\"IT network\" width=\"400\" height=\"342\" srcset=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/\u0131t-\u015febeke.jpg 400w, https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/\u0131t-\u015febeke-300x257.jpg 300w, https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/\u0131t-\u015febeke-171x146.jpg 171w, https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/\u0131t-\u015febeke-50x43.jpg 50w, https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/\u0131t-\u015febeke-88x75.jpg 88w\" sizes=\"auto, (max-width:767px) 400px, 400px\" \/><\/a><\/p>\n","protected":false},"excerpt":{"rendered":"<p>International regulations define low-voltage distribution networks in three ways. According to the TS 3994 standard, these distribution networks are named as follows. The application of grounding<span class=\"excerpt-hellip\"> [\u2026]<\/span><\/p>\n","protected":false},"author":1,"featured_media":51213,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_joinchat":[],"footnotes":""},"categories":[193],"tags":[],"class_list":["post-51211","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-general"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v19.2.1 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Grounding Types and Distribution Networks<\/title>\n<meta name=\"description\" content=\"When selecting an LV surge arrester system, the grounding structure of the system is of great importance. Product selection and installation must be carried out according to the characteristics of TT, TN, TNC, and TNS systems.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/yilkomer.com\/en\/grounding-types-and-distribution-networks\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Grounding Types and Distribution Networks\" \/>\n<meta property=\"og:description\" content=\"International regulations define low-voltage distribution networks in three ways. According to the TS 3994 standard, these distribution networks are named\" \/>\n<meta property=\"og:url\" content=\"https:\/\/yilkomer.com\/en\/grounding-types-and-distribution-networks\/\" \/>\n<meta property=\"og:site_name\" content=\"Y\u0131lkomer\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/yilkomer\" \/>\n<meta property=\"article:published_time\" content=\"2015-09-17T10:37:16+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-12-18T20:12:59+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/al\u00e7ak-gerilim-sebekesi.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"533\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/grounding-types-and-distribution-networks\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/grounding-types-and-distribution-networks\\\/\"},\"author\":{\"name\":\"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#\\\/schema\\\/person\\\/1378732ec91a59af36092fedd9f6f871\"},\"headline\":\"Grounding Types and Distribution Networks\",\"datePublished\":\"2015-09-17T10:37:16+00:00\",\"dateModified\":\"2025-12-18T20:12:59+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/grounding-types-and-distribution-networks\\\/\"},\"wordCount\":332,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/grounding-types-and-distribution-networks\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/yilkomer.com\\\/wp-content\\\/uploads\\\/2015\\\/09\\\/al\u00e7ak-gerilim-sebekesi.jpg\",\"articleSection\":[\"General\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/yilkomer.com\\\/en\\\/grounding-types-and-distribution-networks\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/grounding-types-and-distribution-networks\\\/\",\"url\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/grounding-types-and-distribution-networks\\\/\",\"name\":\"Grounding Types and Distribution Networks\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/grounding-types-and-distribution-networks\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/grounding-types-and-distribution-networks\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/yilkomer.com\\\/wp-content\\\/uploads\\\/2015\\\/09\\\/al\u00e7ak-gerilim-sebekesi.jpg\",\"datePublished\":\"2015-09-17T10:37:16+00:00\",\"dateModified\":\"2025-12-18T20:12:59+00:00\",\"description\":\"When selecting an LV surge arrester system, the grounding structure of the system is of great importance. Product selection and installation must be carried out according to the characteristics of TT, TN, TNC, and TNS systems.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/grounding-types-and-distribution-networks\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/yilkomer.com\\\/en\\\/grounding-types-and-distribution-networks\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/grounding-types-and-distribution-networks\\\/#primaryimage\",\"url\":\"https:\\\/\\\/yilkomer.com\\\/wp-content\\\/uploads\\\/2015\\\/09\\\/al\u00e7ak-gerilim-sebekesi.jpg\",\"contentUrl\":\"https:\\\/\\\/yilkomer.com\\\/wp-content\\\/uploads\\\/2015\\\/09\\\/al\u00e7ak-gerilim-sebekesi.jpg\",\"width\":800,\"height\":533,\"caption\":\"Al\u00e7ak gerilim \u015febekesi\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/grounding-types-and-distribution-networks\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Ana Sayfa\",\"item\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Grounding Types and Distribution Networks\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/\",\"name\":\"Y\u0131lkomer\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#organization\"},\"alternateName\":\"Y\u0131lkomer\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#organization\",\"name\":\"Yilkomer\",\"url\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/yilkomer.com\\\/wp-content\\\/uploads\\\/2015\\\/01\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/yilkomer.com\\\/wp-content\\\/uploads\\\/2015\\\/01\\\/logo.png\",\"width\":1000,\"height\":189,\"caption\":\"Yilkomer\"},\"image\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#\\\/schema\\\/person\\\/1378732ec91a59af36092fedd9f6f871\",\"name\":\"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi\",\"description\":\"Y\u0131lkomer (Y\u0131ld\u0131r\u0131mdan Korunma Merkezi) \u00fclkemizde y\u0131ld\u0131r\u0131mdan ve a\u015f\u0131r\u0131 gerilimden korunmada teknik eksiklikleri ortadan kald\u0131rarak tamamen standartlar ve m\u00fchendislik hesaplar\u0131na dayanarak sistem kurmay\u0131 hedeflemektedir.\",\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/yilkomer\",\"https:\\\/\\\/www.linkedin.com\\\/profile\\\/view?id=393173773&trk=nav_responsive_tab_profile\",\"https:\\\/\\\/x.com\\\/https:\\\/\\\/twitter.com\\\/yilkomer\",\"admin\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Grounding Types and Distribution Networks","description":"When selecting an LV surge arrester system, the grounding structure of the system is of great importance. Product selection and installation must be carried out according to the characteristics of TT, TN, TNC, and TNS systems.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/yilkomer.com\/en\/grounding-types-and-distribution-networks\/","og_locale":"en_US","og_type":"article","og_title":"Grounding Types and Distribution Networks","og_description":"International regulations define low-voltage distribution networks in three ways. According to the TS 3994 standard, these distribution networks are named","og_url":"https:\/\/yilkomer.com\/en\/grounding-types-and-distribution-networks\/","og_site_name":"Y\u0131lkomer","article_author":"https:\/\/www.facebook.com\/yilkomer","article_published_time":"2015-09-17T10:37:16+00:00","article_modified_time":"2025-12-18T20:12:59+00:00","og_image":[{"width":800,"height":533,"url":"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/al\u00e7ak-gerilim-sebekesi.jpg","type":"image\/jpeg"}],"author":"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi","twitter_misc":{"Written by":"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/yilkomer.com\/en\/grounding-types-and-distribution-networks\/#article","isPartOf":{"@id":"https:\/\/yilkomer.com\/en\/grounding-types-and-distribution-networks\/"},"author":{"name":"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi","@id":"https:\/\/yilkomer.com\/en\/#\/schema\/person\/1378732ec91a59af36092fedd9f6f871"},"headline":"Grounding Types and Distribution Networks","datePublished":"2015-09-17T10:37:16+00:00","dateModified":"2025-12-18T20:12:59+00:00","mainEntityOfPage":{"@id":"https:\/\/yilkomer.com\/en\/grounding-types-and-distribution-networks\/"},"wordCount":332,"commentCount":0,"publisher":{"@id":"https:\/\/yilkomer.com\/en\/#organization"},"image":{"@id":"https:\/\/yilkomer.com\/en\/grounding-types-and-distribution-networks\/#primaryimage"},"thumbnailUrl":"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/al\u00e7ak-gerilim-sebekesi.jpg","articleSection":["General"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/yilkomer.com\/en\/grounding-types-and-distribution-networks\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/yilkomer.com\/en\/grounding-types-and-distribution-networks\/","url":"https:\/\/yilkomer.com\/en\/grounding-types-and-distribution-networks\/","name":"Grounding Types and Distribution Networks","isPartOf":{"@id":"https:\/\/yilkomer.com\/en\/#website"},"primaryImageOfPage":{"@id":"https:\/\/yilkomer.com\/en\/grounding-types-and-distribution-networks\/#primaryimage"},"image":{"@id":"https:\/\/yilkomer.com\/en\/grounding-types-and-distribution-networks\/#primaryimage"},"thumbnailUrl":"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/al\u00e7ak-gerilim-sebekesi.jpg","datePublished":"2015-09-17T10:37:16+00:00","dateModified":"2025-12-18T20:12:59+00:00","description":"When selecting an LV surge arrester system, the grounding structure of the system is of great importance. Product selection and installation must be carried out according to the characteristics of TT, TN, TNC, and TNS systems.","breadcrumb":{"@id":"https:\/\/yilkomer.com\/en\/grounding-types-and-distribution-networks\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/yilkomer.com\/en\/grounding-types-and-distribution-networks\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/yilkomer.com\/en\/grounding-types-and-distribution-networks\/#primaryimage","url":"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/al\u00e7ak-gerilim-sebekesi.jpg","contentUrl":"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/09\/al\u00e7ak-gerilim-sebekesi.jpg","width":800,"height":533,"caption":"Al\u00e7ak gerilim \u015febekesi"},{"@type":"BreadcrumbList","@id":"https:\/\/yilkomer.com\/en\/grounding-types-and-distribution-networks\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Ana Sayfa","item":"https:\/\/yilkomer.com\/en\/"},{"@type":"ListItem","position":2,"name":"Grounding Types and Distribution Networks"}]},{"@type":"WebSite","@id":"https:\/\/yilkomer.com\/en\/#website","url":"https:\/\/yilkomer.com\/en\/","name":"Y\u0131lkomer","description":"","publisher":{"@id":"https:\/\/yilkomer.com\/en\/#organization"},"alternateName":"Y\u0131lkomer","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/yilkomer.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/yilkomer.com\/en\/#organization","name":"Yilkomer","url":"https:\/\/yilkomer.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/yilkomer.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/01\/logo.png","contentUrl":"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/01\/logo.png","width":1000,"height":189,"caption":"Yilkomer"},"image":{"@id":"https:\/\/yilkomer.com\/en\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/yilkomer.com\/en\/#\/schema\/person\/1378732ec91a59af36092fedd9f6f871","name":"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi","description":"Y\u0131lkomer (Y\u0131ld\u0131r\u0131mdan Korunma Merkezi) \u00fclkemizde y\u0131ld\u0131r\u0131mdan ve a\u015f\u0131r\u0131 gerilimden korunmada teknik eksiklikleri ortadan kald\u0131rarak tamamen standartlar ve m\u00fchendislik hesaplar\u0131na dayanarak sistem kurmay\u0131 hedeflemektedir.","sameAs":["https:\/\/www.facebook.com\/yilkomer","https:\/\/www.linkedin.com\/profile\/view?id=393173773&trk=nav_responsive_tab_profile","https:\/\/x.com\/https:\/\/twitter.com\/yilkomer","admin"]}]}},"_links":{"self":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts\/51211","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/comments?post=51211"}],"version-history":[{"count":2,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts\/51211\/revisions"}],"predecessor-version":[{"id":51235,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts\/51211\/revisions\/51235"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/media\/51213"}],"wp:attachment":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/media?parent=51211"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/categories?post=51211"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/tags?post=51211"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}