{"id":50358,"date":"2014-02-01T13:28:33","date_gmt":"2014-02-01T11:28:33","guid":{"rendered":"https:\/\/yilkomer.com\/izolasyonu-saglayan-yildirim-inis-iletkeni-iscon\/"},"modified":"2025-12-18T17:56:59","modified_gmt":"2025-12-18T14:56:59","slug":"lightning-down-conductor-providing-insulation","status":"publish","type":"post","link":"https:\/\/yilkomer.com\/en\/lightning-down-conductor-providing-insulation\/","title":{"rendered":"Lightning Down Conductor Providing Insulation"},"content":{"rendered":"<p>In our country, <span style=\"color: #ff6600;\"><strong>lightning protection systems<\/strong><\/span> are installed based on the <strong><a title=\"IEC Standards\" href=\"http:\/\/www.iec.ch\/\" target=\"_blank\" rel=\"noopener\">IEC 62305 standard<\/a><\/strong>. This standard provides guidance for passive systems such as cages, meshes, air terminals, and catenary wires. Lightning rod systems commonly encountered in our country are designed based on the NFC 17102 standard. In this article, we would like to bring up a very important topic that is included in the standards and must be emphasized while directing lightning discharge with external lightning protection systems: <strong>\u201cInsulation\u201d<\/strong>.<\/p>\n<p>While the lightning discharge captured by <a title=\"External Lightning Protection\" href=\"https:\/\/yilkomer.com\/en\/external-lightning-protection-systems\/\" target=\"_blank\" rel=\"noopener\"><strong>external lightning protection systems<\/strong><\/a> is conducted down to the grounding area, it may jump to <strong>power<\/strong> and <strong>data<\/strong> lines and often cause serious damage due to coupling effects. In addition, bare conductors installed directly against the building can lead to dangerous outcomes such as fires and risks to human life. Therefore, lightning discharge must be conducted to the ground in an insulated manner, away from the structure. To achieve this, standards provide us with two alternatives.<\/p>\n<ul>\n<li>Using insulated conductors tested at lightning discharge levels ()<\/li>\n<li>Maintaining the \u2018S\u2019 separation distance calculated by considering the physical characteristics of the building using relevant formulas.<\/li>\n<\/ul>\n<h2><strong><span style=\"color: #ff6600;\">Calculation of the S Distance<\/span><\/strong><\/h2>\n<p>Generally, maintaining the \u2018S\u2019 separation distance should be ensured with special insulated products. However, due to application difficulties and the risk of contact caused by bare conductors, and especially due to fire hazards in areas such as fuel stations and filling facilities, the use of an insulated lightning <a title=\"Thermoweld System Equipment\" href=\"https:\/\/yilkomer.com\/en\/thermoweld-system-equipment\/\" target=\"_blank\" rel=\"noopener\"><strong>discharge conductor<\/strong><\/a> is a more common solution.<\/p>\n<div id=\"attachment_3295\" style=\"width: 624px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2014\/02\/Y\u0131ld\u0131r\u0131m1.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-3295\" class=\"wp-image-3295\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2014\/02\/Y\u0131ld\u0131r\u0131m1.jpg\" alt=\"Lightning S Distance\" width=\"614\" height=\"341\" \/><\/a><p id=\"caption-attachment-3295\" class=\"wp-caption-text\">Calculation of lightning and the S distance<\/p><\/div>\n<p>&nbsp;<\/p>\n<p>The S distance is calculated according to <strong>IEC 62305<\/strong>.<\/p>\n<div id=\"attachment_3296\" style=\"width: 282px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2014\/02\/Y\u0131ld\u0131r\u0131m2.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-3296\" class=\"wp-image-3296 size-full\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2014\/02\/Y\u0131ld\u0131r\u0131m2.jpg\" alt=\"How to Calculate the S Distance\" width=\"272\" height=\"179\" srcset=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2014\/02\/Y\u0131ld\u0131r\u0131m2.jpg 272w, https:\/\/yilkomer.com\/wp-content\/uploads\/2014\/02\/Y\u0131ld\u0131r\u0131m2-243x160.jpg 243w\" sizes=\"auto, (max-width:767px) 272px, 272px\" \/><\/a><p id=\"caption-attachment-3296\" class=\"wp-caption-text\">Formula of the S distance<\/p><\/div>\n<p>&nbsp;<\/p>\n<p>Ki: Protection class<\/p>\n<p>Kc: Number of down conductors<\/p>\n<p>Km: Type of conductor used<\/p>\n<h2><strong><span style=\"color: #ff6600;\">Insulated Conductor<\/span><\/strong><\/h2>\n<p>Systems using insulated conductors for down conductors provide \u2018Safety\u2019 in many respects. This is particularly important for areas where technology and people coexist densely, such as military facilities, ammunition depots, GSM towers, <a title=\"Hasanbeyli\/Silivri Wind Power Plants Surge and Lightning Protection System\" href=\"https:\/\/yilkomer.com\/portfolio\/silivri-ruzgar-santralleri-asiri-gerilim-ve-yildirimdan-korunmasi\/\" target=\"_blank\" rel=\"noopener\"><strong>wind turbines<\/strong><\/a>, solar panels, filling facilities, hospitals, schools, technological buildings, and subways. Regardless of the external lightning design\u2014whether cage method or Faraday method\u2014ensuring down conductor insulation and providing symmetrical down conductors from two points are extremely important. Insulated conductors provide insulation for impulses up to 200 kA. Considering that the average impulse in our country is 50 kA and can reach up to 100 kA in southern regions, these systems stand out as a significant method for establishing safe lightning protection systems. However, as we always emphasize, we cannot protect our facilities with external lightning protection systems alone. Lightning protection systems are like a table standing on four legs. To maximize facility safety, internal lightning protection systems, equipotential bonding, and a proper grounding system must also be implemented.<\/p>\n<p>In the table below, you can see the difference between systems with and without S separation distance and systems using <b>insulated conductors<\/b> .<\/p>\n<div id=\"attachment_3298\" style=\"width: 570px\" class=\"wp-caption alignnone\"><a href=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2014\/02\/Y\u0131ld\u0131r\u0131m4.jpg\"><img loading=\"lazy\" decoding=\"async\" aria-describedby=\"caption-attachment-3298\" class=\"wp-image-3298\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2014\/02\/Y\u0131ld\u0131r\u0131m4.jpg\" alt=\"OBO iscon\" width=\"560\" height=\"384\" srcset=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2014\/02\/Y\u0131ld\u0131r\u0131m4.jpg 736w, https:\/\/yilkomer.com\/wp-content\/uploads\/2014\/02\/Y\u0131ld\u0131r\u0131m4-300x206.jpg 300w, https:\/\/yilkomer.com\/wp-content\/uploads\/2014\/02\/Y\u0131ld\u0131r\u0131m4-706x484.jpg 706w, https:\/\/yilkomer.com\/wp-content\/uploads\/2014\/02\/Y\u0131ld\u0131r\u0131m4-697x478.jpg 697w, https:\/\/yilkomer.com\/wp-content\/uploads\/2014\/02\/Y\u0131ld\u0131r\u0131m4-515x353.jpg 515w\" sizes=\"auto, (max-width:767px) 480px, 560px\" \/><\/a><p id=\"caption-attachment-3298\" class=\"wp-caption-text\">Due to fire hazard risks in areas such as fuel stations and filling facilities, the use of insulated lightning discharge conductors is a more common solution.<\/p><\/div>\n<p>&nbsp;<\/p>\n<p>An <strong><a title=\"Protect Your Devices from Overvoltage\" href=\"https:\/\/yilkomer.com\/en\/protect-your-devices-from-overvoltage\/\" target=\"_blank\" rel=\"noopener\">insulated lightning protection system<\/a><\/strong> must be implemented as a whole with all its components. Installing only the conductor may cause malfunctions in the system over time. The insulated system consists entirely of corrosion-resistant insulated products. At the locations where the system is installed, lightning impulses passing through the facility are recorded by the Lightning Recording System and can be provided to you as reports upon request.<\/p>\n<blockquote><p>In conclusion, when lightning protection systems are implemented by providing insulation at the contact surfaces between the structure and down conductors, as stated in the standards, unwanted adverse consequences will be prevented proportionally.<\/p><\/blockquote>\n<p>What must not be forgotten is that <strong><span style=\"color: #ff6600;\">Lightning Protection and Grounding<\/span><\/strong> are systems that must be designed and implemented by expert engineers. Even the smallest clamp used has an impact on the integrity of the entire system; therefore, we kindly ask all sector stakeholders to show due sensitivity on this matter.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>In our country, lightning protection systems are installed based on the IEC 62305 standard. This standard provides guidance for passive systems such as cages, meshes, air<span class=\"excerpt-hellip\"> [\u2026]<\/span><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_joinchat":[],"footnotes":""},"categories":[193],"tags":[],"class_list":["post-50358","post","type-post","status-publish","format-standard","hentry","category-general"],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v19.2.1 (Yoast SEO v27.4) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Lightning Down Conductor Providing Insulation<\/title>\n<meta name=\"description\" content=\"Using an insulated isCon conductor tested at lightning discharge levels enables the lightning discharge to be conducted from the structure to the ground in an insulated manner.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/yilkomer.com\/en\/lightning-down-conductor-providing-insulation\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Lightning Down Conductor Providing Insulation\" \/>\n<meta property=\"og:description\" content=\"In our country, lightning protection systems are installed based on the IEC 62305 standard. This standard provides guidance for passive systems such as\" \/>\n<meta property=\"og:url\" content=\"https:\/\/yilkomer.com\/en\/lightning-down-conductor-providing-insulation\/\" \/>\n<meta property=\"og:site_name\" content=\"Y\u0131lkomer\" \/>\n<meta property=\"article:author\" content=\"https:\/\/www.facebook.com\/yilkomer\" \/>\n<meta property=\"article:published_time\" content=\"2014-02-01T11:28:33+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-12-18T14:56:59+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/02\/yildirim-carpmasi.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"467\" \/>\n\t<meta property=\"og:image:height\" content=\"286\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/lightning-down-conductor-providing-insulation\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/lightning-down-conductor-providing-insulation\\\/\"},\"author\":{\"name\":\"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#\\\/schema\\\/person\\\/1378732ec91a59af36092fedd9f6f871\"},\"headline\":\"Lightning Down Conductor Providing Insulation\",\"datePublished\":\"2014-02-01T11:28:33+00:00\",\"dateModified\":\"2025-12-18T14:56:59+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/lightning-down-conductor-providing-insulation\\\/\"},\"wordCount\":666,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#organization\"},\"articleSection\":[\"General\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/yilkomer.com\\\/en\\\/lightning-down-conductor-providing-insulation\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/lightning-down-conductor-providing-insulation\\\/\",\"url\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/lightning-down-conductor-providing-insulation\\\/\",\"name\":\"Lightning Down Conductor Providing Insulation\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#website\"},\"datePublished\":\"2014-02-01T11:28:33+00:00\",\"dateModified\":\"2025-12-18T14:56:59+00:00\",\"description\":\"Using an insulated isCon conductor tested at lightning discharge levels enables the lightning discharge to be conducted from the structure to the ground in an insulated manner.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/lightning-down-conductor-providing-insulation\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/yilkomer.com\\\/en\\\/lightning-down-conductor-providing-insulation\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/lightning-down-conductor-providing-insulation\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Ana Sayfa\",\"item\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Lightning Down Conductor Providing Insulation\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/\",\"name\":\"Y\u0131lkomer\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#organization\"},\"alternateName\":\"Y\u0131lkomer\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#organization\",\"name\":\"Yilkomer\",\"url\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/yilkomer.com\\\/wp-content\\\/uploads\\\/2015\\\/01\\\/logo.png\",\"contentUrl\":\"https:\\\/\\\/yilkomer.com\\\/wp-content\\\/uploads\\\/2015\\\/01\\\/logo.png\",\"width\":1000,\"height\":189,\"caption\":\"Yilkomer\"},\"image\":{\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/yilkomer.com\\\/en\\\/#\\\/schema\\\/person\\\/1378732ec91a59af36092fedd9f6f871\",\"name\":\"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi\",\"description\":\"Y\u0131lkomer (Y\u0131ld\u0131r\u0131mdan Korunma Merkezi) \u00fclkemizde y\u0131ld\u0131r\u0131mdan ve a\u015f\u0131r\u0131 gerilimden korunmada teknik eksiklikleri ortadan kald\u0131rarak tamamen standartlar ve m\u00fchendislik hesaplar\u0131na dayanarak sistem kurmay\u0131 hedeflemektedir.\",\"sameAs\":[\"https:\\\/\\\/www.facebook.com\\\/yilkomer\",\"https:\\\/\\\/www.linkedin.com\\\/profile\\\/view?id=393173773&trk=nav_responsive_tab_profile\",\"https:\\\/\\\/x.com\\\/https:\\\/\\\/twitter.com\\\/yilkomer\",\"admin\"]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Lightning Down Conductor Providing Insulation","description":"Using an insulated isCon conductor tested at lightning discharge levels enables the lightning discharge to be conducted from the structure to the ground in an insulated manner.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/yilkomer.com\/en\/lightning-down-conductor-providing-insulation\/","og_locale":"en_US","og_type":"article","og_title":"Lightning Down Conductor Providing Insulation","og_description":"In our country, lightning protection systems are installed based on the IEC 62305 standard. This standard provides guidance for passive systems such as","og_url":"https:\/\/yilkomer.com\/en\/lightning-down-conductor-providing-insulation\/","og_site_name":"Y\u0131lkomer","article_author":"https:\/\/www.facebook.com\/yilkomer","article_published_time":"2014-02-01T11:28:33+00:00","article_modified_time":"2025-12-18T14:56:59+00:00","og_image":[{"width":467,"height":286,"url":"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/02\/yildirim-carpmasi.jpg","type":"image\/jpeg"}],"author":"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi","twitter_misc":{"Written by":"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/yilkomer.com\/en\/lightning-down-conductor-providing-insulation\/#article","isPartOf":{"@id":"https:\/\/yilkomer.com\/en\/lightning-down-conductor-providing-insulation\/"},"author":{"name":"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi","@id":"https:\/\/yilkomer.com\/en\/#\/schema\/person\/1378732ec91a59af36092fedd9f6f871"},"headline":"Lightning Down Conductor Providing Insulation","datePublished":"2014-02-01T11:28:33+00:00","dateModified":"2025-12-18T14:56:59+00:00","mainEntityOfPage":{"@id":"https:\/\/yilkomer.com\/en\/lightning-down-conductor-providing-insulation\/"},"wordCount":666,"commentCount":0,"publisher":{"@id":"https:\/\/yilkomer.com\/en\/#organization"},"articleSection":["General"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/yilkomer.com\/en\/lightning-down-conductor-providing-insulation\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/yilkomer.com\/en\/lightning-down-conductor-providing-insulation\/","url":"https:\/\/yilkomer.com\/en\/lightning-down-conductor-providing-insulation\/","name":"Lightning Down Conductor Providing Insulation","isPartOf":{"@id":"https:\/\/yilkomer.com\/en\/#website"},"datePublished":"2014-02-01T11:28:33+00:00","dateModified":"2025-12-18T14:56:59+00:00","description":"Using an insulated isCon conductor tested at lightning discharge levels enables the lightning discharge to be conducted from the structure to the ground in an insulated manner.","breadcrumb":{"@id":"https:\/\/yilkomer.com\/en\/lightning-down-conductor-providing-insulation\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/yilkomer.com\/en\/lightning-down-conductor-providing-insulation\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/yilkomer.com\/en\/lightning-down-conductor-providing-insulation\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Ana Sayfa","item":"https:\/\/yilkomer.com\/en\/"},{"@type":"ListItem","position":2,"name":"Lightning Down Conductor Providing Insulation"}]},{"@type":"WebSite","@id":"https:\/\/yilkomer.com\/en\/#website","url":"https:\/\/yilkomer.com\/en\/","name":"Y\u0131lkomer","description":"","publisher":{"@id":"https:\/\/yilkomer.com\/en\/#organization"},"alternateName":"Y\u0131lkomer","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/yilkomer.com\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/yilkomer.com\/en\/#organization","name":"Yilkomer","url":"https:\/\/yilkomer.com\/en\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/yilkomer.com\/en\/#\/schema\/logo\/image\/","url":"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/01\/logo.png","contentUrl":"https:\/\/yilkomer.com\/wp-content\/uploads\/2015\/01\/logo.png","width":1000,"height":189,"caption":"Yilkomer"},"image":{"@id":"https:\/\/yilkomer.com\/en\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/yilkomer.com\/en\/#\/schema\/person\/1378732ec91a59af36092fedd9f6f871","name":"Y\u0131ld\u0131r\u0131mdan Korunma Merkezi","description":"Y\u0131lkomer (Y\u0131ld\u0131r\u0131mdan Korunma Merkezi) \u00fclkemizde y\u0131ld\u0131r\u0131mdan ve a\u015f\u0131r\u0131 gerilimden korunmada teknik eksiklikleri ortadan kald\u0131rarak tamamen standartlar ve m\u00fchendislik hesaplar\u0131na dayanarak sistem kurmay\u0131 hedeflemektedir.","sameAs":["https:\/\/www.facebook.com\/yilkomer","https:\/\/www.linkedin.com\/profile\/view?id=393173773&trk=nav_responsive_tab_profile","https:\/\/x.com\/https:\/\/twitter.com\/yilkomer","admin"]}]}},"_links":{"self":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts\/50358","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/comments?post=50358"}],"version-history":[{"count":2,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts\/50358\/revisions"}],"predecessor-version":[{"id":50375,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/posts\/50358\/revisions\/50375"}],"wp:attachment":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/media?parent=50358"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/categories?post=50358"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/tags?post=50358"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}