{"id":992739,"date":"2025-10-22T12:52:58","date_gmt":"2025-10-22T09:52:58","guid":{"rendered":"https:\/\/testdijitalist.com\/solutions\/earthing-equipment\/"},"modified":"2026-08-31T08:57:37","modified_gmt":"2026-08-31T05:57:37","slug":"earthing-equipment","status":"publish","type":"page","link":"https:\/\/yilkomer.com\/en\/solutions\/earthing-equipment\/","title":{"rendered":"Earthing Equipment"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-page\" data-elementor-id=\"992739\" class=\"elementor elementor-992739 elementor-94\" data-elementor-post-type=\"page\">\n\t\t\t\t<div class=\"elementor-element elementor-element-637975da e-flex e-con-boxed e-con e-parent\" data-id=\"637975da\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"vamtam-has-theme-widget-styles elementor-element elementor-element-312c475 elementor-widget elementor-widget-text-editor\" data-id=\"312c475\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Earthing is the least visible but most decisive component of an electrical installation.<\/strong> The dispersion of the lightning current into the ground, the safe discharge of fault currents and the protection of human life all depend on this system. However carefully the air terminal is chosen, if the earthing is weak the system will not deliver the protection expected of it.<\/p><p>The correctness and the selection of the equipment used matter as much as the earthing design and its calculations. At Y\u0131lkomer we hold in stock every product needed to earth a facility; alongside this we provide survey, calculation, design and installation support from a single source.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-27b72cea elementor-widget-divider--view-line elementor-widget elementor-widget-divider\" data-id=\"27b72cea\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"divider.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-divider\">\n\t\t\t<span class=\"elementor-divider-separator\">\n\t\t\t\t\t\t<\/span>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3e8ee573 elementor-widget elementor-widget-heading\" data-id=\"3e8ee573\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Four Factors That Determine the Performance of an Earthing System<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-3569477c e-con-full e-flex e-con e-child\" data-id=\"3569477c\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t<div class=\"elementor-element elementor-element-296d3e30 elementor-widget__width-initial elementor-widget-mobile__width-inherit elementor-view-default elementor-position-block-start elementor-mobile-position-block-start elementor-widget elementor-widget-icon-box\" data-id=\"296d3e30\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-icon-box-wrapper\">\n\n\t\t\t\t\t\t<div class=\"elementor-icon-box-icon\">\n\t\t\t\t<span  class=\"elementor-icon\">\n\t\t\t\t<i aria-hidden=\"true\" class=\"vamtamtheme- vamtam-theme-electrician-4\"><\/i>\t\t\t\t<\/span>\n\t\t\t<\/div>\n\t\t\t\n\t\t\t\t\t\t<div class=\"elementor-icon-box-content\">\n\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-icon-box-title\">\n\t\t\t\t\t\t<span  >\n\t\t\t\t\t\t\tSoil Resistivity\t\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/div>\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<p class=\"elementor-icon-box-description\">\n\t\t\t\t\t\tThe same electrode gives a completely different result in sandy soil than in clay soil. The first step in a correct design is to measure the soil resistivity on site. Without this measurement, the number and depth of the electrodes chosen is no more than guesswork; in high-resistivity soils it often falls short.\t\t\t\t\t<\/p>\n\t\t\t\t\n\t\t\t<\/div>\n\t\t\t\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-23cacb86 elementor-widget__width-initial elementor-widget-mobile__width-inherit elementor-view-default elementor-position-block-start elementor-mobile-position-block-start elementor-widget elementor-widget-icon-box\" data-id=\"23cacb86\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-icon-box-wrapper\">\n\n\t\t\t\t\t\t<div class=\"elementor-icon-box-icon\">\n\t\t\t\t<span  class=\"elementor-icon\">\n\t\t\t\t<i aria-hidden=\"true\" class=\"vamtamtheme- vamtam-theme-electrician-4\"><\/i>\t\t\t\t<\/span>\n\t\t\t<\/div>\n\t\t\t\n\t\t\t\t\t\t<div class=\"elementor-icon-box-content\">\n\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-icon-box-title\">\n\t\t\t\t\t\t<span  >\n\t\t\t\t\t\t\tElectrode Selection and Material\t\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/div>\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<p class=\"elementor-icon-box-description\">\n\t\t\t\t\t\tRod electrode, angle-bar electrode, strip conductor or ring earth electrode \u2014 which of these is used is determined by the soil structure, the condition of the existing building and the target resistance. On the material side, hot-dip galvanised steel, copper-bonded steel and solid copper offer different balances of service life and cost.\t\t\t\t\t<\/p>\n\t\t\t\t\n\t\t\t<\/div>\n\t\t\t\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-67840f68 elementor-widget__width-initial elementor-widget-mobile__width-inherit elementor-view-default elementor-position-block-start elementor-mobile-position-block-start elementor-widget elementor-widget-icon-box\" data-id=\"67840f68\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-icon-box-wrapper\">\n\n\t\t\t\t\t\t<div class=\"elementor-icon-box-icon\">\n\t\t\t\t<span  class=\"elementor-icon\">\n\t\t\t\t<i aria-hidden=\"true\" class=\"vamtamtheme- vamtam-theme-electrician-4\"><\/i>\t\t\t\t<\/span>\n\t\t\t<\/div>\n\t\t\t\n\t\t\t\t\t\t<div class=\"elementor-icon-box-content\">\n\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-icon-box-title\">\n\t\t\t\t\t\t<span  >\n\t\t\t\t\t\t\tConnection Quality\t\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/div>\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<p class=\"elementor-icon-box-description\">\n\t\t\t\t\t\tThe weakest point of an earthing network is almost always the connections. Mechanical clamps loosen over time and are open to corrosion; exothermic (thermite) welded connections, by contrast, become one with the conductor, provide the same current-carrying capacity and stay sealed against corrosion underground. At points where dissimilar metals meet, the risk of galvanic corrosion must also be taken into account.\t\t\t\t\t<\/p>\n\t\t\t\t\n\t\t\t<\/div>\n\t\t\t\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5e3b1671 elementor-widget__width-initial elementor-widget-mobile__width-inherit elementor-view-default elementor-position-block-start elementor-mobile-position-block-start elementor-widget elementor-widget-icon-box\" data-id=\"5e3b1671\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"icon-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-icon-box-wrapper\">\n\n\t\t\t\t\t\t<div class=\"elementor-icon-box-icon\">\n\t\t\t\t<span  class=\"elementor-icon\">\n\t\t\t\t<i aria-hidden=\"true\" class=\"vamtamtheme- vamtam-theme-electrician-4\"><\/i>\t\t\t\t<\/span>\n\t\t\t<\/div>\n\t\t\t\n\t\t\t\t\t\t<div class=\"elementor-icon-box-content\">\n\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-icon-box-title\">\n\t\t\t\t\t\t<span  >\n\t\t\t\t\t\t\tMeasurement and Continuity\t\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/div>\n\t\t\t\t\n\t\t\t\t\t\t\t\t\t<p class=\"elementor-icon-box-description\">\n\t\t\t\t\t\tOnce the earthing is buried it disappears from view; for this reason inspection pits and test points must be built into the design from the outset. The resistance and continuity measurements made during commissioning must be recorded and repeated at the periodic inspections.\t\t\t\t\t<\/p>\n\t\t\t\t\n\t\t\t<\/div>\n\t\t\t\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-46300e elementor-widget elementor-widget-heading\" data-id=\"46300e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">The Main Product Groups We Hold in Stock<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"vamtam-has-theme-widget-styles elementor-element elementor-element-25ead72 elementor-widget elementor-widget-text-editor\" data-id=\"25ead72\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The following items are always available from our stock, in a range of sizes:<\/p><ul><li><strong>30\u00d73.5 galvanised earthing tape <\/strong>\u2014 The most widely used cross-section in ring earthing and down conductor applications.<\/li><li><strong>30\u00d73 galvanised earthing tape<\/strong> \u2014 An alternative cross-section chosen according to the project specification.<\/li><li><strong>Copper earth electrode <\/strong>\u2014 For applications in corrosive soils that call for high conductivity and long service life.<\/li><li><strong>Angle-bar earth electrodes <\/strong>\u2014 A profile-type electrode that is easy to drive into hard, stony ground.<\/li><li><strong>Solid copper earthing conductor <\/strong>\u2014 For critical facilities, giving low impedance and a long service life.<\/li><li><strong>Equipotential busbar systems <\/strong>\u2014 The collection point at which the metal parts, the building services and the protective conductors inside a structure are bonded to a common potential.<\/li><li><strong>Lightning air terminal systems <\/strong>\u2014 The terminals and support components that form the air termination points on the roof.<\/li><li><strong>Air terminal base <\/strong>\u2014 Base solutions that hold the terminal in place by weight, without penetrating the roof covering.<\/li><li><strong>Cross connector<\/strong> \u2014 A standards-compliant mechanical connection for tape-to-tape and tape-to-round-conductor joints.<\/li><li><strong>Exothermic welding equipment <\/strong>\u2014 An exothermic welding set with crucible, mould, igniter and powder materials.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class=\"elementor-element elementor-element-6f8f4bb e-flex e-con-boxed e-con e-parent\" data-id=\"6f8f4bb\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-32ca9ba elementor-widget elementor-widget-html\" data-id=\"32ca9ba\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\r\n<!-- YILKOMER \u2014 RELATED PRODUCTS (Grounding Equipment) \u2014 stacked card layout -->\r\n<section id=\"yki-cozum-2\" style=\"max-width:760px;margin:48px auto;padding:0 20px;font-family:inherit;\">\r\n  <div style=\"text-align:center;margin-bottom:28px;\">\r\n    <h2 style=\"font-size:26px;font-weight:700;color:#111827;margin:0 0 8px;\">Related Products<\/h2>\r\n    <p style=\"font-size:15px;color:#6b7280;margin:0;\">Key products used in grounding and equipotential bonding systems<\/p>\r\n  <\/div>\r\n\r\n  <div style=\"display:flex;flex-direction:column;gap:18px;\">\r\n\r\n    <!-- Grounding Electrodes and Rods -->\r\n    <div style=\"background:#fff;border:1px solid #e5e7eb;border-radius:14px;padding:20px;\">\r\n      <h3 style=\"font-size:16px;font-weight:700;color:#111827;margin:0 0 12px;\">Grounding Electrodes and Rods<\/h3>\r\n\r\n      <!-- nVent ERICO Copper-Bonded Ground Rod -->\r\n      <a href=\"https:\/\/yilkomer.com\/en\/products\/nvent-erico-copper-clad-grounding-rod-threaded\/\" style=\"display:flex;align-items:center;gap:12px;text-decoration:none;color:#111827;padding:10px 0;border-bottom:1px solid #f3f4f6;\">\r\n        <img decoding=\"async\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2026\/08\/ph0282.png-1024x1024.webp\" alt=\"nVent ERICO Copper-Bonded Grounding Rod\" style=\"width:46px;height:46px;object-fit:contain;flex-shrink:0;\">\r\n        <span style=\"font-size:14px;line-height:1.35;\">nVent ERICO Copper-Bonded Grounding Rod \u2014 Threaded<\/span>\r\n      <\/a>\r\n\r\n      <!-- Quick Assembly Grounding Rod Set -->\r\n      <a href=\"https:\/\/yilkomer.com\/en\/products\/quick-assembly-earthing-rod-set-o16-mm-diagonal-connector\/\" style=\"display:flex;align-items:center;gap:12px;text-decoration:none;color:#111827;padding:10px 0;\">\r\n        <img decoding=\"async\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2026\/08\/Set-of-earthing-rods-O16-mm-for-quick-assembly-with-diagonal-connector.png\" alt=\"Quick Assembly Grounding Rod Set \u00d816 mm\" style=\"width:46px;height:46px;object-fit:contain;flex-shrink:0;\">\r\n        <span style=\"font-size:14px;line-height:1.35;\">Quick Assembly Grounding Rod Set \u00d816 mm \u2014 With Diagonal Connector<\/span>\r\n      <\/a>\r\n    <\/div>\r\n\r\n\r\n    <!-- Exothermic Welding and Ground Enhancement -->\r\n    <div style=\"background:#fff;border:1px solid #e5e7eb;border-radius:14px;padding:20px;\">\r\n      <h3 style=\"font-size:16px;font-weight:700;color:#111827;margin:0 0 12px;\">Exothermic Welding and Ground Enhancement<\/h3>\r\n\r\n      <!-- Cadweld Plus Impulse -->\r\n      <a href=\"https:\/\/yilkomer.com\/en\/products\/nvent-erico-cadweld-plus-impulse-exothermic-welding-ignition-unit\/\" style=\"display:flex;align-items:center;gap:12px;text-decoration:none;color:#111827;padding:10px 0;border-bottom:1px solid #f3f4f6;\">\r\n        <img decoding=\"async\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2026\/08\/ph39900.png-1024x1024.webp\" alt=\"nVent ERICO Cadweld Plus Impulse\" style=\"width:46px;height:46px;object-fit:contain;flex-shrink:0;\">\r\n        <span style=\"font-size:14px;line-height:1.35;\">nVent ERICO Cadweld Plus Impulse \u2014 Exothermic Welding Ignition Unit<\/span>\r\n      <\/a>\r\n\r\n      <!-- GEM -->\r\n      <a href=\"https:\/\/yilkomer.com\/en\/products\/nvent-erico-gem-ground-enhancement-material\/\" style=\"display:flex;align-items:center;gap:12px;text-decoration:none;color:#111827;padding:10px 0;\">\r\n        <img decoding=\"async\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2026\/08\/ph19871.png-1024x1024.webp\" alt=\"nVent ERICO GEM Ground Enhancement Material\" style=\"width:46px;height:46px;object-fit:contain;flex-shrink:0;\">\r\n        <span style=\"font-size:14px;line-height:1.35;\">nVent ERICO GEM \u2014 Ground Enhancement Material<\/span>\r\n      <\/a>\r\n    <\/div>\r\n\r\n\r\n    <!-- Equipotential Bonding -->\r\n    <div style=\"background:#fff;border:1px solid #e5e7eb;border-radius:14px;padding:20px;\">\r\n      <h3 style=\"font-size:16px;font-weight:700;color:#111827;margin:0 0 12px;\">Equipotential Bonding and Clamps<\/h3>\r\n\r\n      <!-- Grounding Busbar -->\r\n      <a href=\"https:\/\/yilkomer.com\/en\/products\/nvent-erico-grounding-busbar-equipotential-bonding-bar\/\" style=\"display:flex;align-items:center;gap:12px;text-decoration:none;color:#111827;padding:10px 0;border-bottom:1px solid #f3f4f6;\">\r\n        <img decoding=\"async\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2026\/08\/ph22570.png-1024x1024.webp\" alt=\"nVent ERICO Grounding Busbar\" style=\"width:46px;height:46px;object-fit:contain;flex-shrink:0;\">\r\n        <span style=\"font-size:14px;line-height:1.35;\">nVent ERICO Grounding Busbar \u2014 Equipotential Bonding Busbar<\/span>\r\n      <\/a>\r\n\r\n      <!-- Hammerlock -->\r\n      <a href=\"https:\/\/yilkomer.com\/en\/products\/nvent-erico-hammerlock-irreversible-grounding-clamp\/\" style=\"display:flex;align-items:center;gap:12px;text-decoration:none;color:#111827;padding:10px 0;\">\r\n        <img decoding=\"async\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2026\/08\/ph3643.png-1024x1024.webp\" alt=\"nVent ERICO Hammerlock\" style=\"width:46px;height:46px;object-fit:contain;flex-shrink:0;\">\r\n        <span style=\"font-size:14px;line-height:1.35;\">nVent ERICO Hammerlock \u2014 Irreversible Grounding Clamp<\/span>\r\n      <\/a>\r\n    <\/div>\r\n\r\n\r\n    <!-- Flat Conductors -->\r\n    <div style=\"background:#fff;border:1px solid #e5e7eb;border-radius:14px;padding:20px;\">\r\n      <h3 style=\"font-size:16px;font-weight:700;color:#111827;margin:0 0 12px;\">Flat Conductors<\/h3>\r\n\r\n      <!-- StZn -->\r\n      <a href=\"https:\/\/yilkomer.com\/en\/products\/hot-dip-galvanized-strip-conductor-stzn\/\" style=\"display:flex;align-items:center;gap:12px;text-decoration:none;color:#111827;padding:10px 0;border-bottom:1px solid #f3f4f6;\">\r\n        <img decoding=\"async\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2026\/08\/Hot-dip-galvanized-steel-flat-conductor-.png\" alt=\"Hot-Dip Galvanized Steel Flat Conductor StZn\" style=\"width:46px;height:46px;object-fit:contain;flex-shrink:0;\">\r\n        <span style=\"font-size:14px;line-height:1.35;\">Hot-Dip Galvanized Steel Flat Conductor (StZn)<\/span>\r\n      <\/a>\r\n\r\n      <!-- StCu -->\r\n      <a href=\"https:\/\/yilkomer.com\/en\/products\/copper-plated-steel-flat-conductor-stcu\/\" style=\"display:flex;align-items:center;gap:12px;text-decoration:none;color:#111827;padding:10px 0;border-bottom:1px solid #f3f4f6;\">\r\n        <img decoding=\"async\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2026\/08\/Copper-plated-steel-flat-conductor.png\" alt=\"Copper-Plated Steel Flat Conductor StCu\" style=\"width:46px;height:46px;object-fit:contain;flex-shrink:0;\">\r\n        <span style=\"font-size:14px;line-height:1.35;\">Copper-Plated Steel Flat Conductor (StCu)<\/span>\r\n      <\/a>\r\n\r\n      <!-- Cu -->\r\n      <a href=\"https:\/\/yilkomer.com\/en\/products\/copper-strip-conductor-cu\/\" style=\"display:flex;align-items:center;gap:12px;text-decoration:none;color:#111827;padding:10px 0;border-bottom:1px solid #f3f4f6;\">\r\n        <img decoding=\"async\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2026\/08\/Copper-plated-steel-flat-conductor.png\" alt=\"Copper Flat Conductor Cu\" style=\"width:46px;height:46px;object-fit:contain;flex-shrink:0;\">\r\n        <span style=\"font-size:14px;line-height:1.35;\">Copper Flat Conductor (Cu)<\/span>\r\n      <\/a>\r\n\r\n      <!-- Inox -->\r\n      <a href=\"https:\/\/yilkomer.com\/en\/products\/stainless-steel-flat-conductor-inox-v2a-v4a\/\" style=\"display:flex;align-items:center;gap:12px;text-decoration:none;color:#111827;padding:10px 0;\">\r\n        <img decoding=\"async\" src=\"https:\/\/yilkomer.com\/wp-content\/uploads\/2026\/08\/Stainless-steel-flat-conductor.png\" alt=\"Stainless Steel Flat Conductor Inox V2A V4A\" style=\"width:46px;height:46px;object-fit:contain;flex-shrink:0;\">\r\n        <span style=\"font-size:14px;line-height:1.35;\">Stainless Steel Flat Conductor (Inox V2A \/ V4A)<\/span>\r\n      <\/a>\r\n    <\/div>\r\n\r\n    <div style=\"text-align:center;\">\r\n      <a href=\"https:\/\/yilkomer.com\/en\/product-categories\/earthing-and-equipotential-bonding\/\" style=\"display:inline-block;margin-top:2px;font-size:13px;font-weight:600;color:#F07C00;text-decoration:none;\">View All \u2192<\/a>\r\n    <\/div>\r\n\r\n  <\/div>\r\n<\/section>\r\n\r\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Earthing is the least visible but most decisive component of an electrical installation. The dispersion of the lightning current into the ground, the safe discharge of fault currents and the protection of human life all depend on this system. However carefully the air terminal is chosen, if the earthing is weak the system will not&#8230;<\/p>\n","protected":false},"author":1,"featured_media":992738,"parent":992417,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-992739","page","type-page","status-publish","has-post-thumbnail","hentry"],"_links":{"self":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/pages\/992739","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/comments?post=992739"}],"version-history":[{"count":7,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/pages\/992739\/revisions"}],"predecessor-version":[{"id":996336,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/pages\/992739\/revisions\/996336"}],"up":[{"embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/pages\/992417"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/media\/992738"}],"wp:attachment":[{"href":"https:\/\/yilkomer.com\/en\/wp-json\/wp\/v2\/media?parent=992739"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}